Experimental investigation of concrete masonry prisms reinforced with in-line stiffening cages under concentric and eccentric loading

This study investigates the axial and flexural behavior of fully grouted masonry prisms reinforced with pre-tied in-line steel cages. The research examines the influence of reinforcement configuration, tie spacing, and load eccentricity on strength, and stiffness, addressing gaps in the existing literature regarding confinement effects and stiffness evaluation in cage-reinforced masonry. A total of forty fully grouted masonry prisms were tested under concentric and eccentric compression. The specimens were categorized into three groups: reinforced masonry with pre-tied cages (RM-T), conventionally reinforced masonry with central bars (RM), and unreinforced masonry (URM). Axial stiffness under concentric loading was quantified using a secant stiffness approach, while effective flexural stiffness ( ) under eccentric loading was evaluated using strain-based curvature measurements. For concentrically loaded specimens, results show that RM-T prisms exhibited higher axial load capacity and stiffness with lower variability than URM prisms, with tie spacing showing only a small influence on stiffness and axial capacity. For eccentrically loaded specimens, the RM-T prisms consistently showed greater load-carrying capacity than the RM prisms at the same eccentricity, demonstrating the benefit of distributing reinforcement across the section. Increasing eccentricity resulted in a reduction in both and load-carrying capacity for all reinforcement configurations. Across all eccentricities, the measured at failure exceeded the values prescribed by the Canadian standard for masonry structure (CSA S304:24), indicating that the standard-based stiffness is conservative for prism-scale members. • Cage reinforcement improved axial stiffness and enhanced confinement of grouted prisms • Stiffness enhancement was governed primarily by grout confinement rather than the direct axial contribution of longitudinal steel. • Under eccentric loading, cage prisms provided greater moment resistance than single-bar prisms • CSA S304:24 stiffness provisions proved conservative for all tested prisms • A confinement-modified stiffness formulation improved agreement with experimental results and rationalized observed stiffness gains.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2026-03-21
DOI
https://doi.org/10.1016/j.jobe.2026.115892
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation of concrete masonry prisms reinforced with in-line stiffening cages under concentric and eccentric loading

Carlos Cruz-Noguez, Clayton Pettit, Mahmoud Elsayed, Joseph Entz
Journal of Building Engineering
Masonry and Concrete Structural Analysis
article

Experimental investigation of concrete masonry prisms reinforced with in-line stiffening cages under concentric and eccentric loading

Carlos Cruz-Noguez, Clayton Pettit, Mahmoud Elsayed, Joseph Entz
article en

Abstract

This study investigates the axial and flexural behavior of fully grouted masonry prisms reinforced with pre-tied in-line steel cages. The research examines the influence of reinforcement configuration, tie spacing, and load eccentricity on strength, and stiffness, addressing gaps in the existing literature regarding confinement effects and stiffness evaluation in cage-reinforced masonry. A total of forty fully grouted masonry prisms were tested under concentric and eccentric compression. The specimens were categorized into three groups: reinforced masonry with pre-tied cages (RM-T), conventionally reinforced masonry with central bars (RM), and unreinforced masonry (URM). Axial stiffness under concentric loading was quantified using a secant stiffness approach, while effective flexural stiffness ( ) under eccentric loading was evaluated using strain-based curvature measurements. For concentrically loaded specimens, results show that RM-T prisms exhibited higher axial load capacity and stiffness with lower variability than URM prisms, with tie spacing showing only a small influence on stiffness and axial capacity. For eccentrically loaded specimens, the RM-T prisms consistently showed greater load-carrying capacity than the RM prisms at the same eccentricity, demonstrating the benefit of distributing reinforcement across the section. Increasing eccentricity resulted in a reduction in both and load-carrying capacity for all reinforcement configurations. Across all eccentricities, the measured at failure exceeded the values prescribed by the Canadian standard for masonry structure (CSA S304:24), indicating that the standard-based stiffness is conservative for prism-scale members. • Cage reinforcement improved axial stiffness and enhanced confinement of grouted prisms • Stiffness enhancement was governed primarily by grout confinement rather than the direct axial contribution of longitudinal steel. • Under eccentric loading, cage prisms provided greater moment resistance than single-bar prisms • CSA S304:24 stiffness provisions proved conservative for all tested prisms • A confinement-modified stiffness formulation improved agreement with experimental results and rationalized observed stiffness gains.

Journal of Building EngineeringVol. 123
University of Alberta (CA), Dominion (United States) (US)
Sustainable cities and communities
Openalex Percentile: Top 13%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.