Confinement of rubble stone masonry columns with steel-FRCM jackets: Experimental evidence and analytical validation

The structural assessment and retrofitting of irregular stone masonry structures, frequently found in historic urban centres, remain particularly challenging due to its intrinsic heterogeneity and vulnerability. Although Fabric-Reinforced Cementitious Matrix (FRCM) systems were widely investigated for brick and squared-stone masonry, only limited evidence is available for rubble stone masonry. The present study addressed this gap by presenting both an experimental programme and an analytical evaluation of the compressive behaviour of rubble stone masonry columns confined with stainless-steel FRCM jackets. Nine square-section columns (250 × 250 × 700 mm) were tested under axial compression: three were left unconfined as reference specimens and six were confined with one or two continuous reinforcement layers. The results showed that FRCM confinement substantially increased both the peak load capacity (up to ∼27%) and ductility (over twofold), while confirming the non-linear efficiency of confinement, as the second reinforcement layer provided a smaller strength increment but a clear gain in deformability. Failure modes were governed by progressive multi-cracking and edge damage of the jackets, whereas the masonry core determined the ultimate capacity. Additionally, experimental results were benchmarked against existing confinement models and a new analytical formulation developed in this study. The proposed model, explicitly accounting for the frictional interaction between stone and mortar, provided close agreement with the tests, predicting the confined strength within ±10%. • Steel-FRCM jackets markedly enhanced strength and ductility of rubble stone columns. • Double-layer confinement improved deformability more than peak compressive strength. • Failure was governed by masonry-core degradation rather than jacket rupture. • Existing models underestimated confined strength when applied to rubble stone masonry. • A friction-based model predicted confined strength within ±10% of experiments.

Authors

Institutions

Publication Details

Journal
Construction and Building Materials
Published
2026-03-21
DOI
https://doi.org/10.1016/j.conbuildmat.2026.145963
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Confinement of rubble stone masonry columns with steel-FRCM jackets: Experimental evidence and analytical validation

Pietro Mazzuca, Alfredo Micieli, Klajdi Toska, Matteo Mauro
Construction and Building Materials
Masonry and Concrete Structural Analysis
article

Confinement of rubble stone masonry columns with steel-FRCM jackets: Experimental evidence and analytical validation

Pietro Mazzuca, Alfredo Micieli, Klajdi Toska, Matteo Mauro
article en

Abstract

The structural assessment and retrofitting of irregular stone masonry structures, frequently found in historic urban centres, remain particularly challenging due to its intrinsic heterogeneity and vulnerability. Although Fabric-Reinforced Cementitious Matrix (FRCM) systems were widely investigated for brick and squared-stone masonry, only limited evidence is available for rubble stone masonry. The present study addressed this gap by presenting both an experimental programme and an analytical evaluation of the compressive behaviour of rubble stone masonry columns confined with stainless-steel FRCM jackets. Nine square-section columns (250 × 250 × 700 mm) were tested under axial compression: three were left unconfined as reference specimens and six were confined with one or two continuous reinforcement layers. The results showed that FRCM confinement substantially increased both the peak load capacity (up to ∼27%) and ductility (over twofold), while confirming the non-linear efficiency of confinement, as the second reinforcement layer provided a smaller strength increment but a clear gain in deformability. Failure modes were governed by progressive multi-cracking and edge damage of the jackets, whereas the masonry core determined the ultimate capacity. Additionally, experimental results were benchmarked against existing confinement models and a new analytical formulation developed in this study. The proposed model, explicitly accounting for the frictional interaction between stone and mortar, provided close agreement with the tests, predicting the confined strength within ±10%. • Steel-FRCM jackets markedly enhanced strength and ductility of rubble stone columns. • Double-layer confinement improved deformability more than peak compressive strength. • Failure was governed by masonry-core degradation rather than jacket rupture. • Existing models underestimated confined strength when applied to rubble stone masonry. • A friction-based model predicted confined strength within ±10% of experiments.

Construction and Building MaterialsVol. 520
University of Padua (IT), University of Calabria (IT)
Sustainable cities and communities
Openalex Percentile: Top 13%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.