Patient comfort and access site outcomes with a screw-based mechanical radial compression device following transradial coronary intervention: A quasi-randomized study

Objective: To evaluate whether a screw-based mechanical radial compression device improves hemostasis success, patient-reported pain and satisfaction compared with conventional manual compression after transradial coronary intervention.Methods: A prospective, quasi-randomized trial was conducted in 248 patients undergoing percutaneous coronary intervention (PCI).Participants were allocated to either mechanical (n = 124) or manual groups (n = 124) in an 1:1 ratio.The primary outcome was successful hemostasis at 6 hours after compression.Bleeding and hematoma were assessed within 24 hours after the procedure.Pain intensity, discomfort, and overall satisfaction, were also recorded.Betweengroup comparisons were summarized using risk ratios with 95% confidence intervals.Results: Successful hemostasis at 6 hours was significantly higher in the mechanical group compared with the manual group (89.5% vs. 83.9%;p = 0.016).The mechanical group had lower access-site bleeding (5.7% vs. 14.5%, p = 0.02) and fewer hematomas (4.8% vs. 12.1%, p = 0.04).Pain scores were significantly lower with the screw-based device both before (2.0 (1.8) vs. 2.7 (2.2), p = 0.009) and 30 minutes after band removal (1.2 (1.3) vs. 1.9 (2.0), p = 0.005).Patients also reported less discomfort (25.0% vs. 37.1%; p = 0.040) and higher satisfaction (84.7% vs. 67.7%;p = 0.002) in mechanical group.The were no complications related to a screw-based device use.Conclusions: Compared with manual compression, a screw-based device provides superior hemostatic efficacy and reduces access-site complications while significantly improving patient experience, with lower pain during compression and after band removal.

Authors

Publication Details

Journal
Heart Vessels and Transplantation
Published
2026-03-15
DOI
https://doi.org/10.24969/hvt.2026.637
Primary Topic
Vascular Procedures and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient comfort and access site outcomes with a screw-based mechanical radial compression device following transradial coronary intervention: A quasi-randomized study

Khoa Ba Tran, Khuong Dang Tran, Tan M. Nguyen, Hung Quoc Pham et al.
Heart Vessels and Transplantation
Vascular Procedures and Complications
article

Patient comfort and access site outcomes with a screw-based mechanical radial compression device following transradial coronary intervention: A quasi-randomized study

Khoa Ba Tran, Khuong Dang Tran, Tan M. Nguyen, Hung Quoc Pham, Dat Minh Nguyen, Hoa Tran, Nhut Quang Le
article en

Abstract

Objective: To evaluate whether a screw-based mechanical radial compression device improves hemostasis success, patient-reported pain and satisfaction compared with conventional manual compression after transradial coronary intervention.Methods: A prospective, quasi-randomized trial was conducted in 248 patients undergoing percutaneous coronary intervention (PCI).Participants were allocated to either mechanical (n = 124) or manual groups (n = 124) in an 1:1 ratio.The primary outcome was successful hemostasis at 6 hours after compression.Bleeding and hematoma were assessed within 24 hours after the procedure.Pain intensity, discomfort, and overall satisfaction, were also recorded.Betweengroup comparisons were summarized using risk ratios with 95% confidence intervals.Results: Successful hemostasis at 6 hours was significantly higher in the mechanical group compared with the manual group (89.5% vs. 83.9%;p = 0.016).The mechanical group had lower access-site bleeding (5.7% vs. 14.5%, p = 0.02) and fewer hematomas (4.8% vs. 12.1%, p = 0.04).Pain scores were significantly lower with the screw-based device both before (2.0 (1.8) vs. 2.7 (2.2), p = 0.009) and 30 minutes after band removal (1.2 (1.3) vs. 1.9 (2.0), p = 0.005).Patients also reported less discomfort (25.0% vs. 37.1%; p = 0.040) and higher satisfaction (84.7% vs. 67.7%;p = 0.002) in mechanical group.The were no complications related to a screw-based device use.Conclusions: Compared with manual compression, a screw-based device provides superior hemostatic efficacy and reduces access-site complications while significantly improving patient experience, with lower pain during compression and after band removal.

Heart Vessels and TransplantationVol. 0(Ahead of Print)
Good health and well-being
Openalex Percentile: Top 14%
Vascular Procedures and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.