Bernoulli-induced self-cleaning in drainage pipes: visual micro-Venturi validation

ABSTRACT Conceptual diagram showing the self-cleaning mechanism: flow through a Venturi generates shear stress to remove deposits. Standard methods of removing sediment from drainage systems consume significant amounts of energy. This study evaluates a passive self-cleaning mechanism that is operated by the Bernoulli principle through a Venturi contraction, using little or no additional energy. A laboratory-scale micro-Venturi was utilized to quantify the relationship between hydraulically induced wall shear stress (τ) and the removal rate (R) of a surrogate kaolinite deposit. Over the flow rate range of 1–12 L·min−1, τ reached a maximum of 102.1 Pa. A strong linear correlation between τ and R was observed (r = 0.958), with a critical shear stress τ_c ≈ 5.8 Pa sufficient to achieve over 60% deposit removal. From this conclusion, a dimensionless scaling factor, Π = τ/τ_c, is presented to help with the design and application of energy-efficient cleaning technology on other pipes of larger scale and similar geometry.

Institutions

Publication Details

Journal
Water Science & Technology
Published
2026-03-13
DOI
https://doi.org/10.2166/wst.2026.243
Primary Topic
Fecal contamination and water quality
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bernoulli-induced self-cleaning in drainage pipes: visual micro-Venturi validation

Water Science & Technology
Fecal contamination and water quality
article

Bernoulli-induced self-cleaning in drainage pipes: visual micro-Venturi validation

article en

Abstract

ABSTRACT Conceptual diagram showing the self-cleaning mechanism: flow through a Venturi generates shear stress to remove deposits. Standard methods of removing sediment from drainage systems consume significant amounts of energy. This study evaluates a passive self-cleaning mechanism that is operated by the Bernoulli principle through a Venturi contraction, using little or no additional energy. A laboratory-scale micro-Venturi was utilized to quantify the relationship between hydraulically induced wall shear stress (τ) and the removal rate (R) of a surrogate kaolinite deposit. Over the flow rate range of 1–12 L·min−1, τ reached a maximum of 102.1 Pa. A strong linear correlation between τ and R was observed (r = 0.958), with a critical shear stress τ_c ≈ 5.8 Pa sufficient to achieve over 60% deposit removal. From this conclusion, a dimensionless scaling factor, Π = τ/τ_c, is presented to help with the design and application of energy-efficient cleaning technology on other pipes of larger scale and similar geometry.

Water Science & TechnologyVol. 93(6)
Heilongjiang University (CN)
Openalex Percentile: Top 13%
Fecal contamination and water quality
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.