FM-Adapt: Foundation model adaptation with photoacoustic-supervised learning for interventional ultrasound

Foundation models (FMs), such as the Segment Anything Model (SAM), have remarkable capabilities for general-purpose segmentation tasks through large-scale pre-training. However, a substantial domain shift limits their effectiveness in complex medical imaging. Here we introduce FM-Adapt, the first parameter-efficient adaptation of a FM (SAM-based vision transformer) into a resolution-agnostic architecture with photoacoustic (PA)-supervised learning for dual-target interventional ultrasound (US) segmentation. We demonstrate FM-Adapt in the context of PA-supervised interventions, specifically for US-guided needle tracking and simultaneous target identification (breast tumor segmentation). We train once with this unified adaptation framework to produce two specialized model weights: USPA-SAM for real-time tracking of needles and BT-SAM for segmenting breast tumors. This framework utilizes frozen pre-trained encoder components and fine-tunes only the mask decoder, allowing the model to process native (256 × 256) clinical images without spatial degradation while achieving state-of-the-art performance with high computational efficiency. USPA-SAM achieves a mean modified Hausdorff Distance (MHD) of 0.34 mm, a targeting error (TE) of 0.83 mm, and a 100% needle localization success rate (NLSR), outperforming baselines by a factor of 3– 17 × in spatial precision. Notably, on tumor segmentation, BT-SAM achieves Dice scores of 93.6% and 96.3%, along with IoU scores of 89.2% and 94.0%, demonstrating strong generalization to unseen data. This work demonstrates that our models achieve a 27 × improvement in computational efficiency to process native clinical images at 34 FPS on a single GPU to enable real-time clinical adaptation.

Authors

Institutions

Publication Details

Journal
Photoacoustics
Published
2026-03-21
DOI
https://doi.org/10.1016/j.pacs.2026.100822
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FM-Adapt: Foundation model adaptation with photoacoustic-supervised learning for interventional ultrasound

Praveenbalaji Rajendran, Manojit Pramanik, Jahid Hasan, Ying Cai
Photoacoustics
Photoacoustic and Ultrasonic Imaging
article

FM-Adapt: Foundation model adaptation with photoacoustic-supervised learning for interventional ultrasound

Praveenbalaji Rajendran, Manojit Pramanik, Jahid Hasan, Ying Cai
article en

Abstract

Foundation models (FMs), such as the Segment Anything Model (SAM), have remarkable capabilities for general-purpose segmentation tasks through large-scale pre-training. However, a substantial domain shift limits their effectiveness in complex medical imaging. Here we introduce FM-Adapt, the first parameter-efficient adaptation of a FM (SAM-based vision transformer) into a resolution-agnostic architecture with photoacoustic (PA)-supervised learning for dual-target interventional ultrasound (US) segmentation. We demonstrate FM-Adapt in the context of PA-supervised interventions, specifically for US-guided needle tracking and simultaneous target identification (breast tumor segmentation). We train once with this unified adaptation framework to produce two specialized model weights: USPA-SAM for real-time tracking of needles and BT-SAM for segmenting breast tumors. This framework utilizes frozen pre-trained encoder components and fine-tunes only the mask decoder, allowing the model to process native (256 × 256) clinical images without spatial degradation while achieving state-of-the-art performance with high computational efficiency. USPA-SAM achieves a mean modified Hausdorff Distance (MHD) of 0.34 mm, a targeting error (TE) of 0.83 mm, and a 100% needle localization success rate (NLSR), outperforming baselines by a factor of 3– 17 × in spatial precision. Notably, on tumor segmentation, BT-SAM achieves Dice scores of 93.6% and 96.3%, along with IoU scores of 89.2% and 94.0%, demonstrating strong generalization to unseen data. This work demonstrates that our models achieve a 27 × improvement in computational efficiency to process native clinical images at 34 FPS on a single GPU to enable real-time clinical adaptation.

PhotoacousticsVol. 49
Emory University (US), Iowa State University (US)
Openalex Percentile: Top 14%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.