Scaling Surface-Guided Radiation Therapy to Larger Lung Cancer Cohorts: Frameless Immobilization and Enhanced Setup Accuracy

<b>Objectives:</b> This study aimed to evaluate the setup accuracy and intrafractional geometric stability of surface-guided radiation therapy (SGRT) under frameless immobilization in lung cancer radiotherapy and to assess its clinical utility in a relatively large patient cohort. <b>Materials and Methods:</b> A total of 678 treatment fractions from 52 patients with primary non-small cell lung cancer (NSCLC), treated between October 2024 and November 2025, were retrospectively analyzed. Patient setup was performed using SGRT with the Identify system, and cone-beam computed tomography (CBCT) served as the reference for internal target localization Intrafractional setup displacements, center-of-mass (COM) shifts, residual setup errors, and intrafractional clinical target volume (CTV) variations were evaluated. Spatial agreement between planned and intrafractional tumor volumes was quantified using the Dice Similarity Coefficient (DSC). <b>Results:</b> The mean CBCT-based intrafractional shifts were -0.01 mm (vertical), 0.03 mm (longitudinal), and 0.01 mm (lateral), indicating negligible systematic errors. The greatest variability was observed in the longitudinal direction (standard deviation, 1.32 mm), with a maximum displacement of 4.58 mm. COM-based analysis demonstrated near-zero mean displacements in all directions, with standard deviations ranging from 0.01 to 0.02 mm. DSC values ranged from 0.91 to 0.98, with a mean of 0.96, indicating excellent spatial agreement between planned and intrafractional tumor volumes. Residual setup errors were predominantly within ±1 mm, and the mean intrafractional CTV volume change was minimal (0.27 cm<sup>3</sup>). <b>Conclusions:</b> SGRT-based frameless lung cancer radiotherapy demonstrated high setup accuracy and robust intrafractional geometric stability. Although slightly greater variability was observed in the longitudinal direction, overall positional deviations and volumetric changes remained within clinically acceptable limits. These findings support the feasibility of integrating SGRT with CBCT-guided radiotherapy and suggest potential benefits for workflow efficiency and planning target volume margin optimization.

Authors

Institutions

Publication Details

Journal
Life
Published
2026-03-20
DOI
https://doi.org/10.3390/life16030517
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scaling Surface-Guided Radiation Therapy to Larger Lung Cancer Cohorts: Frameless Immobilization and Enhanced Setup Accuracy

Eun Hee Jeon, Hakyoung Kim, Sun Myung Kim, Jeongeun Hwang et al.
Life
Advanced Radiotherapy Techniques
article

Scaling Surface-Guided Radiation Therapy to Larger Lung Cancer Cohorts: Frameless Immobilization and Enhanced Setup Accuracy

Eun Hee Jeon, Hakyoung Kim, Sun Myung Kim, Jeongeun Hwang, Jang Bo Shim, Yeong Cheol Lee
article en

Abstract

<b>Objectives:</b> This study aimed to evaluate the setup accuracy and intrafractional geometric stability of surface-guided radiation therapy (SGRT) under frameless immobilization in lung cancer radiotherapy and to assess its clinical utility in a relatively large patient cohort. <b>Materials and Methods:</b> A total of 678 treatment fractions from 52 patients with primary non-small cell lung cancer (NSCLC), treated between October 2024 and November 2025, were retrospectively analyzed. Patient setup was performed using SGRT with the Identify system, and cone-beam computed tomography (CBCT) served as the reference for internal target localization Intrafractional setup displacements, center-of-mass (COM) shifts, residual setup errors, and intrafractional clinical target volume (CTV) variations were evaluated. Spatial agreement between planned and intrafractional tumor volumes was quantified using the Dice Similarity Coefficient (DSC). <b>Results:</b> The mean CBCT-based intrafractional shifts were -0.01 mm (vertical), 0.03 mm (longitudinal), and 0.01 mm (lateral), indicating negligible systematic errors. The greatest variability was observed in the longitudinal direction (standard deviation, 1.32 mm), with a maximum displacement of 4.58 mm. COM-based analysis demonstrated near-zero mean displacements in all directions, with standard deviations ranging from 0.01 to 0.02 mm. DSC values ranged from 0.91 to 0.98, with a mean of 0.96, indicating excellent spatial agreement between planned and intrafractional tumor volumes. Residual setup errors were predominantly within ±1 mm, and the mean intrafractional CTV volume change was minimal (0.27 cm<sup>3</sup>). <b>Conclusions:</b> SGRT-based frameless lung cancer radiotherapy demonstrated high setup accuracy and robust intrafractional geometric stability. Although slightly greater variability was observed in the longitudinal direction, overall positional deviations and volumetric changes remained within clinically acceptable limits. These findings support the feasibility of integrating SGRT with CBCT-guided radiotherapy and suggest potential benefits for workflow efficiency and planning target volume margin optimization.

LifeVol. 16(3)
Soonchunhyang University (KR), Korea University Medical Center (KR), Kyonggi University (KR)
Good health and well-being
Openalex Percentile: Top 12%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.