Performance of Cast-in-Place Repair Concrete Incorporating Recycled Coarse Aggregate Under Partially Exposed Sulfate Corrosion Environments

To investigate the sulfate corrosion resistance of cast-in-place repair concrete incorporating recycled coarse aggregate (RCA) under partially exposed conditions, cast-in-place repair concrete specimens with different RCA contents (0%, 30%, and 50%) were immersed in Na2SO4 solution. The study systematically investigated the changes in apparent morphology, dimensions, mass, and mechanical properties of the specimens under sulfate corrosion. SEM, XRD, TG/DTG, and MIP were used to characterize the microstructure and mineral composition of the specimens at different corrosion ages. Results indicate that RCA cast-in-place repair concrete partially exposed to a sulfate corrosion environment undergoes coupled physical and chemical corrosion, and the interfacial zone between the recycled aggregate concrete to the base concrete represents the most vulnerable region in the composite system. Incorporating 30% RCA can effectively reduce the degradation rate of specimens under sulfate corrosion, enhance the compactness of the bonding interface, and optimize the interfacial bond strength, compressive strength, and pore structure of the specimens. Excessive RCA content disrupts the internal pore structure, accelerates sulfate ion ingress, and weakens the interfacial bond strength. The presence of RCA significantly reduces the interfacial shear strength of the specimens. After 360 days of sulfate corrosion, specimens featuring 30% and 50% RCA contents exhibit a reduction in shear strength of 15.91% and 40.0%, respectively, compared with the 0% RCA content specimen. Research findings provide a theoretical basis for the application of RCA in concrete repair engineering.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-03-20
DOI
https://doi.org/10.3390/buildings16061239
Primary Topic
Recycled Aggregate Concrete Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of Cast-in-Place Repair Concrete Incorporating Recycled Coarse Aggregate Under Partially Exposed Sulfate Corrosion Environments

Zhibao Nie, Gaowen Zhao, Lingxuan Yue, Gang Gu et al.
Buildings
Recycled Aggregate Concrete Performance
article

Performance of Cast-in-Place Repair Concrete Incorporating Recycled Coarse Aggregate Under Partially Exposed Sulfate Corrosion Environments

Zhibao Nie, Gaowen Zhao, Lingxuan Yue, Gang Gu, Jianfeng Zhu, Zhe Li, Zhilong Chen, Long Chen, Shijun Ding
article en

Abstract

To investigate the sulfate corrosion resistance of cast-in-place repair concrete incorporating recycled coarse aggregate (RCA) under partially exposed conditions, cast-in-place repair concrete specimens with different RCA contents (0%, 30%, and 50%) were immersed in Na2SO4 solution. The study systematically investigated the changes in apparent morphology, dimensions, mass, and mechanical properties of the specimens under sulfate corrosion. SEM, XRD, TG/DTG, and MIP were used to characterize the microstructure and mineral composition of the specimens at different corrosion ages. Results indicate that RCA cast-in-place repair concrete partially exposed to a sulfate corrosion environment undergoes coupled physical and chemical corrosion, and the interfacial zone between the recycled aggregate concrete to the base concrete represents the most vulnerable region in the composite system. Incorporating 30% RCA can effectively reduce the degradation rate of specimens under sulfate corrosion, enhance the compactness of the bonding interface, and optimize the interfacial bond strength, compressive strength, and pore structure of the specimens. Excessive RCA content disrupts the internal pore structure, accelerates sulfate ion ingress, and weakens the interfacial bond strength. The presence of RCA significantly reduces the interfacial shear strength of the specimens. After 360 days of sulfate corrosion, specimens featuring 30% and 50% RCA contents exhibit a reduction in shear strength of 15.91% and 40.0%, respectively, compared with the 0% RCA content specimen. Research findings provide a theoretical basis for the application of RCA in concrete repair engineering.

BuildingsVol. 16(6)
North China Electric Power University (CN), Chang'an University (CN), China Railway Group (China) (CN)
Openalex Percentile: Top 14%
Recycled Aggregate Concrete Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.