Effects of frontal and sagittal inclination angles on the thermal performance of a single-loop pulsating heat pipe

• The effect of novel sagittal inclination on pulsating heat pipe is studied. • Sagittal inclination yields lower thermal resistance than frontal. • Fluid velocity is mapped quantitatively against inclination angle. • Flow regime differences between sagittal and frontal inclinations are discussed. In contrast to multi-turn pulsating heat pipes, the thermal characteristics of single-loop pulsating heat pipes (SLPHPs) exhibit an extremely strong dependence on orientation. While the effects of the frontal inclination angle (FIA) have been extensively studied, the role of the sagittal inclination angle (SIA) remains largely unexamined. This work systematically investigates the impact of FIAs and SIAs, varied from 0° to 90° in 15° increments, on the thermal performance of a SLPHP across heat inputs of 10–70 W. Through simultaneous flow visualization and thermal resistance measurements, it was determined that at a 30 W heat input an SIA of 60° yields optimal thermal performance by establishing a stable unidirectional circulation. Although dry-out did not occur at SIA = 0°, thermal performance was substantially inferior to that at the optimal angle. For the FIA, the optimum was also observed at 60°, attributed to the combined effects of gravity and bubble-nose shape on flow velocity. Moreover, in contrast to the SIA case, FIA = 0° resulted in dry-out. A comparative analysis of all orientations confirmed that SIA = 60° provides the lowest thermal resistance, followed by FIA = 60°. These findings provide new insights into the orientation-dependent behavior of SLPHPs and offer practical guidance for their application.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2026-03-20
DOI
https://doi.org/10.1016/j.tsep.2026.104652
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of frontal and sagittal inclination angles on the thermal performance of a single-loop pulsating heat pipe

Luca Cattani, Mahmoud Rahmati, Rasoul Fallahzadeh, Fabio Bozzoli
Thermal Science and Engineering Progress
Heat Transfer and Boiling Studies
article

Effects of frontal and sagittal inclination angles on the thermal performance of a single-loop pulsating heat pipe

Luca Cattani, Mahmoud Rahmati, Rasoul Fallahzadeh, Fabio Bozzoli
article en

Abstract

• The effect of novel sagittal inclination on pulsating heat pipe is studied. • Sagittal inclination yields lower thermal resistance than frontal. • Fluid velocity is mapped quantitatively against inclination angle. • Flow regime differences between sagittal and frontal inclinations are discussed. In contrast to multi-turn pulsating heat pipes, the thermal characteristics of single-loop pulsating heat pipes (SLPHPs) exhibit an extremely strong dependence on orientation. While the effects of the frontal inclination angle (FIA) have been extensively studied, the role of the sagittal inclination angle (SIA) remains largely unexamined. This work systematically investigates the impact of FIAs and SIAs, varied from 0° to 90° in 15° increments, on the thermal performance of a SLPHP across heat inputs of 10–70 W. Through simultaneous flow visualization and thermal resistance measurements, it was determined that at a 30 W heat input an SIA of 60° yields optimal thermal performance by establishing a stable unidirectional circulation. Although dry-out did not occur at SIA = 0°, thermal performance was substantially inferior to that at the optimal angle. For the FIA, the optimum was also observed at 60°, attributed to the combined effects of gravity and bubble-nose shape on flow velocity. Moreover, in contrast to the SIA case, FIA = 0° resulted in dry-out. A comparative analysis of all orientations confirmed that SIA = 60° provides the lowest thermal resistance, followed by FIA = 60°. These findings provide new insights into the orientation-dependent behavior of SLPHPs and offer practical guidance for their application.

Thermal Science and Engineering ProgressVol. 73
University of Parma (IT), Graduate University of Advanced Technology (IR), University of Florence (IT)
Affordable and clean energy
Openalex Percentile: Top 14%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.