Benchmarking size-exclusion chromatography columns for the analysis of therapeutic peptides and model oligonucleotides

Eleven modern size-exclusion chromatography (SEC) columns, including prototype columns designed to minimize non-specific interactions, were systematically evaluated for the analysis of peptides and oligonucleotides. Column physical properties and chromatographic performance were assessed under various mobile phase conditions. Notably, a reduced plate height close to 1 was achieved for one prototype column, representing a marked improvement over typical SEC performance (2 < h<sub>min</sub> < 3). Mobile phase composition was optimized to balance chromatographic efficiency and analyte denaturation. The most denaturing conditions (30 % acetonitrile, 0.1 % trifluoroacetic acid) provided the best performance for linear, macrocyclic, disulfide-constrained, and lipid-conjugated peptides by effectively suppressing hydrophobic and ionic interactions. Columns with pore sizes ≥ 100 Å showed optimal performance, with UP-SW2000, Biozen dSEC-1, and BioCore SEC-120 columns (100-125 Å) yielding the best results. Column and mobile phase selection were particularly critical for hydrophobic peptides such as liraglutide and semaglutide; for these analytes, a phosphate-based mobile phase containing 20 % isopropanol was proposed to limit denaturation and potentially enable the characterization of non-covalent aggregates. For oligonucleotides, mobile phase composition had a limited impact, whereas stationary phase chemistry was decisive. Only two columns (UP-SW2000 and ACQUITY Premier SEC 125 Å) provided acceptable separations, enabling resolution of n-2 and n-3 shortmer impurities of 20-mer linear and structured oligonucleotides with resolutions close to 1. Coupling two 150-mm SEC columns in series further enhanced shortmer separation within 30 min.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2026-03-21
DOI
https://doi.org/10.1016/j.chroma.2026.466909
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Benchmarking size-exclusion chromatography columns for the analysis of therapeutic peptides and model oligonucleotides

Alexandre Goyon, Davy Guillarme, Kelly ZHANG, Mathias BUFF
Journal of Chromatography A
Analytical Chemistry and Chromatography
article

Benchmarking size-exclusion chromatography columns for the analysis of therapeutic peptides and model oligonucleotides

Alexandre Goyon, Davy Guillarme, Kelly ZHANG, Mathias BUFF
article en

Abstract

Eleven modern size-exclusion chromatography (SEC) columns, including prototype columns designed to minimize non-specific interactions, were systematically evaluated for the analysis of peptides and oligonucleotides. Column physical properties and chromatographic performance were assessed under various mobile phase conditions. Notably, a reduced plate height close to 1 was achieved for one prototype column, representing a marked improvement over typical SEC performance (2 < h<sub>min</sub> < 3). Mobile phase composition was optimized to balance chromatographic efficiency and analyte denaturation. The most denaturing conditions (30 % acetonitrile, 0.1 % trifluoroacetic acid) provided the best performance for linear, macrocyclic, disulfide-constrained, and lipid-conjugated peptides by effectively suppressing hydrophobic and ionic interactions. Columns with pore sizes ≥ 100 Å showed optimal performance, with UP-SW2000, Biozen dSEC-1, and BioCore SEC-120 columns (100-125 Å) yielding the best results. Column and mobile phase selection were particularly critical for hydrophobic peptides such as liraglutide and semaglutide; for these analytes, a phosphate-based mobile phase containing 20 % isopropanol was proposed to limit denaturation and potentially enable the characterization of non-covalent aggregates. For oligonucleotides, mobile phase composition had a limited impact, whereas stationary phase chemistry was decisive. Only two columns (UP-SW2000 and ACQUITY Premier SEC 125 Å) provided acceptable separations, enabling resolution of n-2 and n-3 shortmer impurities of 20-mer linear and structured oligonucleotides with resolutions close to 1. Coupling two 150-mm SEC columns in series further enhanced shortmer separation within 30 min.

Journal of Chromatography AVol. 1775
University of Geneva (CH)
Reduced inequalities
Openalex Percentile: Top 13%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.