Visibility and relaxation time mapping of 3-D printed polymers using ultrashort echo time MRI

The increasing interest in, and affordability of, 3-D printing has made fast prototyping and manufacturing of components and accessories increasingly popular in MRI research. In this work, visibility in magnetic resonance images and T<sub>1</sub> and T<sub>2</sub><sup>∗</sup> relaxation times of 3-D printed thermoplastic materials were investigated with multi-band sweep imaging with Fourier transformation (MB-SWIFT) and single point imaging (SPI). Ten commonly available 3-D printable plastics were investigated at 9.4 T. T<sub>1</sub> relaxation times were estimated with inversion recovery (IR-LL) and saturation recovery Look-Locker (SR-LL) as well as variable flip angle (VFA) MB-SWIFT techniques. T<sub>2</sub><sup>∗</sup> relaxation times were estimated from SPI data. It was observed that acrylonitrile styrene acrylate (ASA), high impact polystyrene (HIPS), acrylonitrile butadiene styrene (ABS) and some poly(lactic acid) (PLA) -based filaments as well as a proprietary thermoplastic formulation generated detectable signal making them "MRI-visible". Glycol-modified polyethylene terephthalate (PET-G) and nylon -based filaments as well as some PLA formulations were observed to be "MRI-invisible" with minimal to non-existent signal. T<sub>1</sub> parameters were estimated to be between 463 and 773 ms (VFA), 520-1004 ms (IR-LL) and 222-296 ms (SR-LL). Average T<sub>2</sub><sup>∗</sup> relaxation times with SPI were between 69 and 273 μs. The results provide a quantitative basis for selecting fused deposition modeling (FDM) materials for ultrashort echo time MRI applications and highlight the importance of both pulse sequence and material composition when designing MRI-compatible structures.

Authors

Institutions

Publication Details

Journal
Journal of Magnetic Resonance
Published
2026-03-21
DOI
https://doi.org/10.1016/j.jmr.2026.108059
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visibility and relaxation time mapping of 3-D printed polymers using ultrashort echo time MRI

Teemu Tuomainen, Mikko J. Nissi, Olli Nykänen, Antti Aarnio
Journal of Magnetic Resonance
Advanced MRI Techniques and Applications
article

Visibility and relaxation time mapping of 3-D printed polymers using ultrashort echo time MRI

Teemu Tuomainen, Mikko J. Nissi, Olli Nykänen, Antti Aarnio
article en

Abstract

The increasing interest in, and affordability of, 3-D printing has made fast prototyping and manufacturing of components and accessories increasingly popular in MRI research. In this work, visibility in magnetic resonance images and T<sub>1</sub> and T<sub>2</sub><sup>∗</sup> relaxation times of 3-D printed thermoplastic materials were investigated with multi-band sweep imaging with Fourier transformation (MB-SWIFT) and single point imaging (SPI). Ten commonly available 3-D printable plastics were investigated at 9.4 T. T<sub>1</sub> relaxation times were estimated with inversion recovery (IR-LL) and saturation recovery Look-Locker (SR-LL) as well as variable flip angle (VFA) MB-SWIFT techniques. T<sub>2</sub><sup>∗</sup> relaxation times were estimated from SPI data. It was observed that acrylonitrile styrene acrylate (ASA), high impact polystyrene (HIPS), acrylonitrile butadiene styrene (ABS) and some poly(lactic acid) (PLA) -based filaments as well as a proprietary thermoplastic formulation generated detectable signal making them "MRI-visible". Glycol-modified polyethylene terephthalate (PET-G) and nylon -based filaments as well as some PLA formulations were observed to be "MRI-invisible" with minimal to non-existent signal. T<sub>1</sub> parameters were estimated to be between 463 and 773 ms (VFA), 520-1004 ms (IR-LL) and 222-296 ms (SR-LL). Average T<sub>2</sub><sup>∗</sup> relaxation times with SPI were between 69 and 273 μs. The results provide a quantitative basis for selecting fused deposition modeling (FDM) materials for ultrashort echo time MRI applications and highlight the importance of both pulse sequence and material composition when designing MRI-compatible structures.

Journal of Magnetic ResonanceVol. 387
University of Eastern Finland (FI), University of Oulu (FI)
Affordable and clean energy
Openalex Percentile: Top 15%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.