Comparative Dynamic Response Analysis of Fixed-Base vs. Base-Isolated Steel-Concrete Composite Frames Under Seismic Excitation

Objectives: The study compares a Lead Rubber Bearing (LRB) base isolated system with a traditional fixed-base system in order to assess the seismic resistance of a G+12 high-rise steel-concrete composite structure. The main objective of the study is to analyze the decrease in seismic requirements and evaluating the capability of LRB for safeguarding vital urban infrastructure. Methods: To capture the nonlinear hysteretic behavior of an LRB isolator, it was analyzed and designed in ABAQUS software. The comparative time history analysis was carried out in ETABS software using IS 1893:2016 guidelines. Storey drift, displacement, peak floor acceleration and base shear are among the measures used to evaluate the structural reaction. Findings: The LRB isolator system performed better, reducing storey drift by 10.83% (X), while the structure’s base reactions reduced by 20.86% (X) and 3.95% (Y). The reaction of the building was successfully moved away from hazardous earthquake frequencies, although lateral displacement increased by 38.82% and the natural time period extended by 24.53%. The implementation of LRB base isolation resulted in a major reduction of internal forces in the structural beams. The bending moment decreased by 19.24% and also the shear force decreased by 7.97% compared to the fixed-base structure. Novelty: The study integrates nonlinear isolator features derived from ABAQUS into ETABS time history analysis to give a localized high reliability comparison specifically for high rise composite structures. It highlighted the critical "acceleration attenuation" effect, proving that LRB base isolation is essential in composite design to transition from life-safety to modern functional recovery standards. Keywords: Lead rubber bearing, Composite structure, Base isolation, Storey drift, Time history analysis

Authors

Institutions

Publication Details

Journal
Indian Journal of Science and Technology
Published
2026-03-24
DOI
https://doi.org/10.17485/ijst/v19i9.1989
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Dynamic Response Analysis of Fixed-Base vs. Base-Isolated Steel-Concrete Composite Frames Under Seismic Excitation

Manish Haveri, R K Chethan Gowda, H R Dileepgowda
Indian Journal of Science and Technology
Seismic Performance and Analysis
article

Comparative Dynamic Response Analysis of Fixed-Base vs. Base-Isolated Steel-Concrete Composite Frames Under Seismic Excitation

Manish Haveri, R K Chethan Gowda, H R Dileepgowda
article en

Abstract

Objectives: The study compares a Lead Rubber Bearing (LRB) base isolated system with a traditional fixed-base system in order to assess the seismic resistance of a G+12 high-rise steel-concrete composite structure. The main objective of the study is to analyze the decrease in seismic requirements and evaluating the capability of LRB for safeguarding vital urban infrastructure. Methods: To capture the nonlinear hysteretic behavior of an LRB isolator, it was analyzed and designed in ABAQUS software. The comparative time history analysis was carried out in ETABS software using IS 1893:2016 guidelines. Storey drift, displacement, peak floor acceleration and base shear are among the measures used to evaluate the structural reaction. Findings: The LRB isolator system performed better, reducing storey drift by 10.83% (X), while the structure’s base reactions reduced by 20.86% (X) and 3.95% (Y). The reaction of the building was successfully moved away from hazardous earthquake frequencies, although lateral displacement increased by 38.82% and the natural time period extended by 24.53%. The implementation of LRB base isolation resulted in a major reduction of internal forces in the structural beams. The bending moment decreased by 19.24% and also the shear force decreased by 7.97% compared to the fixed-base structure. Novelty: The study integrates nonlinear isolator features derived from ABAQUS into ETABS time history analysis to give a localized high reliability comparison specifically for high rise composite structures. It highlighted the critical "acceleration attenuation" effect, proving that LRB base isolation is essential in composite design to transition from life-safety to modern functional recovery standards. Keywords: Lead rubber bearing, Composite structure, Base isolation, Storey drift, Time history analysis

Indian Journal of Science and TechnologyVol. 19(9)
M S Ramaiah University of Applied Sciences (IN)
Openalex Percentile: Top 14%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.