Embedded Hardware Architecture development for Electrocardiogram Signal Filtering

Numerous are the embedded systems that have been suggested to filter the ECG signal from the noises that get added during its recording. However, hardware, time, and power consumption are still challenging because of the high computational complexity of the considered algorithms. The DWT-ADTF is a recent low-complexity technique that has shown its efficiency and effectiveness against ECG noises. This paper presents a high-quality and real-time embedded architecture for denoising ECG signal. The system consists of a hardware architecture implemented in the Cyclone V DE10 FPGA. The denoising quality assessment is based on the MIT-BIH arrhythmia and variant noise types for variant input SNR values. The effectiveness of our embedded system is evaluated through the RMSE and SNR out. The proposed architecture provides significant results that convinces its suitability for real-time ECG monitoring systems.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-03-16
DOI
https://doi.org/10.1051/e3sconf/202669801003/pdf
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Embedded Hardware Architecture development for Electrocardiogram Signal Filtering

Boujemaa Nassiri, Wissam Jenkal, Bouchra Bendahane, Mostafa Laaboubi
Springer Link (Chiba Institute of Technology)
ECG Monitoring and Analysis
article

Embedded Hardware Architecture development for Electrocardiogram Signal Filtering

Boujemaa Nassiri, Wissam Jenkal, Bouchra Bendahane, Mostafa Laaboubi
article en

Abstract

Numerous are the embedded systems that have been suggested to filter the ECG signal from the noises that get added during its recording. However, hardware, time, and power consumption are still challenging because of the high computational complexity of the considered algorithms. The DWT-ADTF is a recent low-complexity technique that has shown its efficiency and effectiveness against ECG noises. This paper presents a high-quality and real-time embedded architecture for denoising ECG signal. The system consists of a hardware architecture implemented in the Cyclone V DE10 FPGA. The denoising quality assessment is based on the MIT-BIH arrhythmia and variant noise types for variant input SNR values. The effectiveness of our embedded system is evaluated through the RMSE and SNR out. The proposed architecture provides significant results that convinces its suitability for real-time ECG monitoring systems.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 25%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.