Embedded Hardware Architecture development for Electrocardiogram Signal Filtering
Numerous are the embedded systems that have been suggested to filter the ECG signal from the noises that get added during its recording. However, hardware, time, and power consumption are still challenging because of the high computational complexity of the considered algorithms. The DWT-ADTF is a recent low-complexity technique that has shown its efficiency and effectiveness against ECG noises. This paper presents a high-quality and real-time embedded architecture for denoising ECG signal. The system consists of a hardware architecture implemented in the Cyclone V DE10 FPGA. The denoising quality assessment is based on the MIT-BIH arrhythmia and variant noise types for variant input SNR values. The effectiveness of our embedded system is evaluated through the RMSE and SNR out. The proposed architecture provides significant results that convinces its suitability for real-time ECG monitoring systems.
Authors
- Boujemaa Nassiri (ORCID: https://orcid.org/0009-0007-8838-8239)
- Wissam Jenkal (ORCID: https://orcid.org/0000-0002-6050-0168)
- Bouchra Bendahane
- Mostafa Laaboubi
Publication Details
- Journal
- Springer Link (Chiba Institute of Technology)
- Published
- 2026-03-16
- DOI
- https://doi.org/10.1051/e3sconf/202669801003/pdf
- Primary Topic
- ECG Monitoring and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00