Investigating discrepancies in accuracy, agreement and interpretability for single-frame embryo classification tasks conducted by embryologists and deep learning models

Introduction Artificial intelligence tools show promise in supporting clinical decision making, but their safe use requires evaluation of not only accuracy, but also agreement with experts and interpretability of model decisions. The aim of this study was to evaluate the accuracy and agreement of human embryologists and deep learning models in embryo stage classification, and to explore interpretability through explainable artificial intelligence. Methods A retrospective, single-center study used single-frame embryo images ( n = 245) classified according to developmental stage by three embryologists and two deep learning models, ResNet-34 and VGG16. Accuracy and agreement among all operators was evaluated, along with an assessment of interpretability with regards to model-generated explanations for spatial attention. Results Embryologists achieved higher accuracy (89.9%) than ResNet-34 (78.8%, p < 0.001) and VGG16 (74.3%, p < 0.001), while overall agreement with the reference standard remained excellent for all operators ( κ ≥0.932). Stage-wise agreement was consistently stronger among embryologists than DL models ( κ = 0.778–0.952 vs. 0.385–0.681). ResNet-34 Grad-CAMs were rated biologically relevant more often than VGG16 (89% vs. 59%, p < 0.001), yet interpretability did not consistently align with accuracy. Analysis of spatial overlap between model generated explanations was weak and observed to be lowest at the blastocyst stage, despite perfect model accuracy. Conclusions These findings highlight the need for evaluation frameworks that integrate accuracy, agreement and interpretability to support safe and transparent development of artificial intelligence tools in assisted reproduction technology.

Authors

Institutions

Publication Details

Journal
Frontiers in Reproductive Health
Published
2026-03-03
DOI
https://doi.org/10.3389/frph.2026.1778326
Primary Topic
Reproductive Biology and Fertility
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating discrepancies in accuracy, agreement and interpretability for single-frame embryo classification tasks conducted by embryologists and deep learning models

Radhika Kakulavarapu, Mario Iliceto, Trine B. Haugen, Akriti Sharma et al.
Frontiers in Reproductive Health
Reproductive Biology and Fertility
article

Investigating discrepancies in accuracy, agreement and interpretability for single-frame embryo classification tasks conducted by embryologists and deep learning models

Radhika Kakulavarapu, Mario Iliceto, Trine B. Haugen, Akriti Sharma, Mette H. Stensen, Erwan Delbarre, David Jahanlu, Michael A. Riegler
article en

Abstract

Introduction Artificial intelligence tools show promise in supporting clinical decision making, but their safe use requires evaluation of not only accuracy, but also agreement with experts and interpretability of model decisions. The aim of this study was to evaluate the accuracy and agreement of human embryologists and deep learning models in embryo stage classification, and to explore interpretability through explainable artificial intelligence. Methods A retrospective, single-center study used single-frame embryo images ( n = 245) classified according to developmental stage by three embryologists and two deep learning models, ResNet-34 and VGG16. Accuracy and agreement among all operators was evaluated, along with an assessment of interpretability with regards to model-generated explanations for spatial attention. Results Embryologists achieved higher accuracy (89.9%) than ResNet-34 (78.8%, p < 0.001) and VGG16 (74.3%, p < 0.001), while overall agreement with the reference standard remained excellent for all operators ( κ ≥0.932). Stage-wise agreement was consistently stronger among embryologists than DL models ( κ = 0.778–0.952 vs. 0.385–0.681). ResNet-34 Grad-CAMs were rated biologically relevant more often than VGG16 (89% vs. 59%, p < 0.001), yet interpretability did not consistently align with accuracy. Analysis of spatial overlap between model generated explanations was weak and observed to be lowest at the blastocyst stage, despite perfect model accuracy. Conclusions These findings highlight the need for evaluation frameworks that integrate accuracy, agreement and interpretability to support safe and transparent development of artificial intelligence tools in assisted reproduction technology.

Frontiers in Reproductive HealthVol. 8
OsloMet – Oslo Metropolitan University (NO), Simula Research Laboratory (NO), Croatian Hydrographic Institute (HR), Metropolitan University (BD), Universidad Metropolitana (PR)
Peace, Justice and strong institutions
Openalex Percentile: Top 20%
Reproductive Biology and Fertility
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.