Deliverable D5.5 - Report on monitoring activities

This document reports on the monitoring activities performed during and after the renovation works in the pilot building located in Via Acquicella Porto 27/H, Catania.The monitoring activities were intended to verify the thermal comfort in the apartments after the building renovation with the e-SAFE solutions, the energy performance of the new thermal systems, and the consequent energy savings. To this aim, a specific monitoring system was designed and installed to measure the indoor environmental parameters (air temperature, relative humidity) and the main relevant parameters for the thermal system (water temperatures, electricity consumption, electricity production from PV). Other measurements allowed to verify the U-value of the walls after the installation of the e-CLT panels. Finally, questionnaires were handed out to the residents to verify their degree of satisfaction with the duration of the renovation works, and the disruption they suffered because of it.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-30
DOI
https://doi.org/10.5281/zenodo.19114711
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deliverable D5.5 - Report on monitoring activities

Giovanni Semprini, Vincenzo Costanzo, Gianpiero Evola, Michele Torrisi
Zenodo (CERN European Organization for Nuclear Research)
Building Energy and Comfort Optimization
article

Deliverable D5.5 - Report on monitoring activities

Giovanni Semprini, Vincenzo Costanzo, Gianpiero Evola, Michele Torrisi
article en

Abstract

This document reports on the monitoring activities performed during and after the renovation works in the pilot building located in Via Acquicella Porto 27/H, Catania.The monitoring activities were intended to verify the thermal comfort in the apartments after the building renovation with the e-SAFE solutions, the energy performance of the new thermal systems, and the consequent energy savings. To this aim, a specific monitoring system was designed and installed to measure the indoor environmental parameters (air temperature, relative humidity) and the main relevant parameters for the thermal system (water temperatures, electricity consumption, electricity production from PV). Other measurements allowed to verify the U-value of the walls after the installation of the e-CLT panels. Finally, questionnaires were handed out to the residents to verify their degree of satisfaction with the duration of the renovation works, and the disruption they suffered because of it.

Zenodo (CERN European Organization for Nuclear Research)
University of Catania (IT), University of Bologna (IT)
Affordable and clean energy
Openalex Percentile: Top 29%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.