Theoretical Verification of Coil-Array-Based 3D Magnetic Particle Imaging Technology

To enable real-time three-dimensional (3D) magnetic particle imaging (MPI) based on the field-free line (FFL), we propose a novel 3D MPI strategy that employs tomographic encoding through the spatially specific sensitivities of a receive coil array. Based on the spatially specific sensitivity encoding (SSSE) principle of the multi-channel receive coil array, 3D reconstruction can be achieved with only a 2D translational scan of the magnetic FFL. This approach reduces the scanning dimensionality by one compared to conventional parallel-beam tomography, offering a new paradigm for rapid, real-time 3D imaging. During reconstruction, multi-channel projection images transform the 3D inverse problem into a series of 1D inverse problems, significantly reducing computational complexity. Finally, the feasibility of sensitivity?based spatial encoding was validated in simulation experiments, demonstrating its broad application prospects and innovative value for 3D MPI imaging.

Authors

Institutions

Publication Details

Journal
Infinite Science GmbH
Published
2025-11-03
DOI
https://doi.org/10.18416/ijmpi.2026.2603016
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theoretical Verification of Coil-Array-Based 3D Magnetic Particle Imaging Technology

Dong Liang, YuZhou Wang, Ning He, Yihan Wang et al.
Infinite Science GmbH
Characterization and Applications of Magnetic Nanoparticles
article

Theoretical Verification of Coil-Array-Based 3D Magnetic Particle Imaging Technology

Dong Liang, YuZhou Wang, Ning He, Yihan Wang, Jinna Hu, Yao Tong, Shouping Zhu, Kun Liu, Dinghong Duan
article en

Abstract

To enable real-time three-dimensional (3D) magnetic particle imaging (MPI) based on the field-free line (FFL), we propose a novel 3D MPI strategy that employs tomographic encoding through the spatially specific sensitivities of a receive coil array. Based on the spatially specific sensitivity encoding (SSSE) principle of the multi-channel receive coil array, 3D reconstruction can be achieved with only a 2D translational scan of the magnetic FFL. This approach reduces the scanning dimensionality by one compared to conventional parallel-beam tomography, offering a new paradigm for rapid, real-time 3D imaging. During reconstruction, multi-channel projection images transform the 3D inverse problem into a series of 1D inverse problems, significantly reducing computational complexity. Finally, the feasibility of sensitivity?based spatial encoding was validated in simulation experiments, demonstrating its broad application prospects and innovative value for 3D MPI imaging.

Infinite Science GmbH
Xidian University (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 36%
Characterization and Applications of Magnetic Nanoparticles
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.