Design of electric and remote operating vehicles battery carrier by using small aluminum closed-cell foam blocks shielded by aluminum tubes

Aluminum closed-cell foam blocks (ACCFBs) are small blocks of foam shielded with small aluminum (Al) tubes developed to enhance the energy absorption of Al foam in limited volumes, such as one cubic inch. It is designed to overcome the problems of the high cost of production, maintenance, and heat insulation properties of foam sheets. Al blocks ideas quoted from human and animal bone parts, and it is designed to absorb energy laterally. This work presents the designs of remote operating vehicles (ROVs) and electric vehicles (EVs) battery carriers, constructed from a cube block of ACCFBs and two Al sheets. The carrier design is based on the properties of Al foam blocks. It is designed to withstand temperatures up to 120 °C. The carrier idea relies on replacing large sheets of Al foam with small, distributed blocks. It has good energy absorption, and at the same time, it helps solve the problems of harness design for crossing wires in narrow areas, such as in ROVs. The results show that the ROVs battery carrier made from the Al sandwich panel (AFS) needs 900 s to transfer 120 °C from the upper sheet to the lower sheet, while the carrier made from ACCFBs with the same volume needs 40 s only. It can also bear a load of up to 0.8 kN and has a working strength δ<sub>working</sub>: 1.093 MPa. The EVs battery carrier can bear a load of 117 kN (about 25 times the battery weight) at yield strength (0.45 MPa), and it has a δ<sub>working</sub>: 0.516 MPa. The calculated total time of cooling for the conduction and forced convection for both the ROVs and EVs carriers at a cooling temperature of 25 °C and at air velocity 1 m/s were 4:31 min and 32:25 min, and at 2 m/s were 3:15 min and 20:41 min, respectively, at a summer working temperature of 40 °C.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-17
DOI
https://doi.org/10.1038/s41598-026-39720-z
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of electric and remote operating vehicles battery carrier by using small aluminum closed-cell foam blocks shielded by aluminum tubes

Ahmed Ismail Zaky Farahat, Mohamed H. Dadoura, M. R. Taha, Ramadan N. Elshaer et al.
Scientific Reports
Cellular and Composite Structures
article

Design of electric and remote operating vehicles battery carrier by using small aluminum closed-cell foam blocks shielded by aluminum tubes

Ahmed Ismail Zaky Farahat, Mohamed H. Dadoura, M. R. Taha, Ramadan N. Elshaer, Zaid Ali Al-Saady
article en

Abstract

Aluminum closed-cell foam blocks (ACCFBs) are small blocks of foam shielded with small aluminum (Al) tubes developed to enhance the energy absorption of Al foam in limited volumes, such as one cubic inch. It is designed to overcome the problems of the high cost of production, maintenance, and heat insulation properties of foam sheets. Al blocks ideas quoted from human and animal bone parts, and it is designed to absorb energy laterally. This work presents the designs of remote operating vehicles (ROVs) and electric vehicles (EVs) battery carriers, constructed from a cube block of ACCFBs and two Al sheets. The carrier design is based on the properties of Al foam blocks. It is designed to withstand temperatures up to 120 °C. The carrier idea relies on replacing large sheets of Al foam with small, distributed blocks. It has good energy absorption, and at the same time, it helps solve the problems of harness design for crossing wires in narrow areas, such as in ROVs. The results show that the ROVs battery carrier made from the Al sandwich panel (AFS) needs 900 s to transfer 120 °C from the upper sheet to the lower sheet, while the carrier made from ACCFBs with the same volume needs 40 s only. It can also bear a load of up to 0.8 kN and has a working strength δ<sub>working</sub>: 1.093 MPa. The EVs battery carrier can bear a load of 117 kN (about 25 times the battery weight) at yield strength (0.45 MPa), and it has a δ<sub>working</sub>: 0.516 MPa. The calculated total time of cooling for the conduction and forced convection for both the ROVs and EVs carriers at a cooling temperature of 25 °C and at air velocity 1 m/s were 4:31 min and 32:25 min, and at 2 m/s were 3:15 min and 20:41 min, respectively, at a summer working temperature of 40 °C.

Scientific ReportsVol. 16(1)
Cairo University (EG), Iraq University College (IQ), Central Metallurgical Research and Development Institute (EG), Tabbin Institute for Metallurgical Studies (EG)
Affordable and clean energy
Openalex Percentile: Top 19%
Cellular and Composite Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.