Development and internal validation of a deep learning algorithm for intraoperative arterial pressure-based stroke volume index estimation in children: a single-center retrospective study

Despite the need for continuous, accurate, and minimally invasive cardiac output measurement in pediatric patients, no recommended methods currently exist. This study aimed to develop and validate a deep learning (DL)-based algorithm that utilizes a minimally invasive arterial pressure waveform to measure pediatric stroke volume index (SVI) accurately. A total of 70 pediatric operations (on 67 patients) were included, with a median age of 6 years. We derived stroke volume (SV) from the Doppler-based stroke distance and aortic cross-sectional area, and then adjusted it to the SVI using body surface area. The arterial pressure waveform and patient demographics were used to predict SVI. The model was validated using error, Bland-Altman, four-quadrant plot, cycle-to-cycle variability, and sensitivity analyses. A saliency map was used to visualize the model’s comprehension of the waveform. The DL model demonstrated a mean absolute error of 4.1 ± 2.8 mL/m2. The limit of agreement (LOA) ranged from − 11.23 ± 0.01 mL/m2 to 8.7 ± 0.1 mL/m2, which was ± 28.6% of bias. In the sensitivity and saliency map analyses, the model effectively extracted features from the arterial pressure waveform. The deep learning model showed promising accuracy (LOA < 30%) in estimating SVI in children. However, its ability to track rapid hemodynamic changes is limited in some cases. Further improvement will be useful for optimizing systemic oxygen delivery and enhancing patient outcomes in pediatric care.

Authors

Institutions

Publication Details

Journal
BMC Medical Informatics and Decision Making
Published
2026-03-17
DOI
https://doi.org/10.1186/s12911-026-03428-x
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and internal validation of a deep learning algorithm for intraoperative arterial pressure-based stroke volume index estimation in children: a single-center retrospective study

Sang‐Hwan Ji, Young‐Eun Jang, E. Edmund Kim, Hyun-Lim Yang et al.
BMC Medical Informatics and Decision Making
Hemodynamic Monitoring and Therapy
article

Development and internal validation of a deep learning algorithm for intraoperative arterial pressure-based stroke volume index estimation in children: a single-center retrospective study

Sang‐Hwan Ji, Young‐Eun Jang, E. Edmund Kim, Hyun-Lim Yang, Chul-Woo Jung, Hee-Soo Kim, Min-Soo Kim, Hyung-Chul Lee
article en

Abstract

Despite the need for continuous, accurate, and minimally invasive cardiac output measurement in pediatric patients, no recommended methods currently exist. This study aimed to develop and validate a deep learning (DL)-based algorithm that utilizes a minimally invasive arterial pressure waveform to measure pediatric stroke volume index (SVI) accurately. A total of 70 pediatric operations (on 67 patients) were included, with a median age of 6 years. We derived stroke volume (SV) from the Doppler-based stroke distance and aortic cross-sectional area, and then adjusted it to the SVI using body surface area. The arterial pressure waveform and patient demographics were used to predict SVI. The model was validated using error, Bland-Altman, four-quadrant plot, cycle-to-cycle variability, and sensitivity analyses. A saliency map was used to visualize the model’s comprehension of the waveform. The DL model demonstrated a mean absolute error of 4.1 ± 2.8 mL/m2. The limit of agreement (LOA) ranged from − 11.23 ± 0.01 mL/m2 to 8.7 ± 0.1 mL/m2, which was ± 28.6% of bias. In the sensitivity and saliency map analyses, the model effectively extracted features from the arterial pressure waveform. The deep learning model showed promising accuracy (LOA < 30%) in estimating SVI in children. However, its ability to track rapid hemodynamic changes is limited in some cases. Further improvement will be useful for optimizing systemic oxygen delivery and enhancing patient outcomes in pediatric care.

BMC Medical Informatics and Decision Making
Korea Advanced Institute of Science and Technology (KR), Chungnam National University (KR), Seoul National University Hospital (KR)
Good health and well-being
Openalex Percentile: Top 19%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.