A Universal Buffer System for Native LC–MS Analysis of Antibody-Based Therapeutics

Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful analytical technique for analyzing biological macromolecules. A long-standing challenge has been applying LC-MS at physiological pH under native conditions using volatile buffers. The predominant "buffer" used, ammonium acetate (AmAc, p<i>K</i><sub>a</sub> 4.75 for acetic acid and 9.25 for ammonium), does not offer sufficient buffering capacity in the physiological pH range of 7.0-7.4. To address this, we evaluated a set of fluorinated ethylamines, 2-fluoroethylamine (MFEA), 2,2-difluoroethylamine (DFEA), and 2,2,2-trifluoroethylamine (TFEA), producing conjugate acids with p<i>K</i><sub>a</sub> values of 8.9, 7.2, and 5.5, respectively, that together provide buffering across the 4.5-9.8 pH range. We show that protein separations on strong cation- and anion-exchange resins in these volatile mobile phases perform comparably to traditional nonvolatile buffers, with similar elution profiles and analyte elution ranking, albeit with slightly broader peaks. Using fully volatile gradients of pH or ionic strength, we chromatographically resolved charge variants of protein analytes such as mAbs and bovine serum albumin. For many of the eluting LC peaks, we obtained high-resolution mass spectra capable of resolving glycoforms of antibodies. Hydrophobic interaction chromatography (HIC) in volatile mobile phases preserved native separation order and further resolved drug-to-antibody ratio (DAR) species of the antibody-drug conjugate brentuximab-vedotin. For each chromatography modality we further compare innovator and biosimilar antibodies, demonstrating the reproducibility of results in the proposed volatile compounds. Together, our results establish fluorinated ethylamines, in combination with ammonium acetate, as a universal volatile buffer system for native LC-MS, broadly applicable across major chromatographic modalities.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-03-17
DOI
https://doi.org/10.1021/jasms.6c00028
Primary Topic
Biosimilars and Bioanalytical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Universal Buffer System for Native LC–MS Analysis of Antibody-Based Therapeutics

Algirdas Vėlyvis, B. Davis, Siavash Vahidi, Jagandeep S. Saraya et al.
Journal of the American Society for Mass Spectrometry
Biosimilars and Bioanalytical Methods
article

A Universal Buffer System for Native LC–MS Analysis of Antibody-Based Therapeutics

Algirdas Vėlyvis, B. Davis, Siavash Vahidi, Jagandeep S. Saraya, Kent R. Vosper, Derek K. O′Flaherty
article en

Abstract

Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful analytical technique for analyzing biological macromolecules. A long-standing challenge has been applying LC-MS at physiological pH under native conditions using volatile buffers. The predominant "buffer" used, ammonium acetate (AmAc, p<i>K</i><sub>a</sub> 4.75 for acetic acid and 9.25 for ammonium), does not offer sufficient buffering capacity in the physiological pH range of 7.0-7.4. To address this, we evaluated a set of fluorinated ethylamines, 2-fluoroethylamine (MFEA), 2,2-difluoroethylamine (DFEA), and 2,2,2-trifluoroethylamine (TFEA), producing conjugate acids with p<i>K</i><sub>a</sub> values of 8.9, 7.2, and 5.5, respectively, that together provide buffering across the 4.5-9.8 pH range. We show that protein separations on strong cation- and anion-exchange resins in these volatile mobile phases perform comparably to traditional nonvolatile buffers, with similar elution profiles and analyte elution ranking, albeit with slightly broader peaks. Using fully volatile gradients of pH or ionic strength, we chromatographically resolved charge variants of protein analytes such as mAbs and bovine serum albumin. For many of the eluting LC peaks, we obtained high-resolution mass spectra capable of resolving glycoforms of antibodies. Hydrophobic interaction chromatography (HIC) in volatile mobile phases preserved native separation order and further resolved drug-to-antibody ratio (DAR) species of the antibody-drug conjugate brentuximab-vedotin. For each chromatography modality we further compare innovator and biosimilar antibodies, demonstrating the reproducibility of results in the proposed volatile compounds. Together, our results establish fluorinated ethylamines, in combination with ammonium acetate, as a universal volatile buffer system for native LC-MS, broadly applicable across major chromatographic modalities.

Journal of the American Society for Mass Spectrometry
University of Guelph (CA)
Openalex Percentile: Top 18%
Biosimilars and Bioanalytical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.