Improving Patient Safety Through EMR-smart Pump Interoperability

Smart infusion pumps are widely used to reduce medication errors. When integrated with electronic medical records (EMR), they support a closed-loop medication management system. This study evaluates the impact of EMR-smart pump interoperability on patient safety and user acceptability in a multicenter Australian health service. A comparative study was conducted using baseline data from a tertiary hospital without smart pump integration (December 2021 to July 2022) and post-implementation data from the newly established digital cardiac hospital (March 2023 to December 2023). Both sites utilized a coronary care-specific medication library to ensure consistency. The evaluation focused on key indicators such as medication library compliance, the frequency of pump reprogramming and high-risk medication alerts, the number of keystrokes required for programming, and the rate of alert overrides. An anonymous survey captured nursing staff perceptions related to satisfaction, workflow efficiency, and confidence in using the pump systems. Following the implementation EMR-smart pump interoperability, medication library compliance improved significantly, rising from 93% to 97%, P<.0001. Alerts related to pump reprogramming and high-risk medications also increased, suggesting enhanced safety monitoring. At the same time, programming became more efficient, with the average number of keystrokes required dropping from 13±3.4 to 3±1.2, P<.0001. However, despite these gains, survey responses revealed a decline in clinician's perceived ease of use (from 90% to 45%, P<.0001) and confidence in programming (93% to 65%, P<.0001). While the rate of cancelled infusions alerts (20% vs. 14%, P<.0001) and all other nonspecific pump alerts (23% vs. 16%, P<.0001) reduced. The integration of EMR-smart pump interoperability enhances medication safety by increasing the frequency of clinical alerts and reducing manual data entry. However, this advancement may introduce usability challenges that impact staff confidence and workflow. These findings highlight the importance of balancing technological integration with user experience to optimize patient safety outcomes.

Authors

Institutions

Publication Details

Journal
CIN Computers Informatics Nursing
Published
2026-03-17
DOI
https://doi.org/10.1097/cin.0000000000001514
Primary Topic
Patient Safety and Medication Errors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Patient Safety Through EMR-smart Pump Interoperability

Viviane Khalil, Julie P. Ngo, Amelia Rattle, Madonna Dixon
CIN Computers Informatics Nursing
Patient Safety and Medication Errors
article

Improving Patient Safety Through EMR-smart Pump Interoperability

Viviane Khalil, Julie P. Ngo, Amelia Rattle, Madonna Dixon
article en

Abstract

Smart infusion pumps are widely used to reduce medication errors. When integrated with electronic medical records (EMR), they support a closed-loop medication management system. This study evaluates the impact of EMR-smart pump interoperability on patient safety and user acceptability in a multicenter Australian health service. A comparative study was conducted using baseline data from a tertiary hospital without smart pump integration (December 2021 to July 2022) and post-implementation data from the newly established digital cardiac hospital (March 2023 to December 2023). Both sites utilized a coronary care-specific medication library to ensure consistency. The evaluation focused on key indicators such as medication library compliance, the frequency of pump reprogramming and high-risk medication alerts, the number of keystrokes required for programming, and the rate of alert overrides. An anonymous survey captured nursing staff perceptions related to satisfaction, workflow efficiency, and confidence in using the pump systems. Following the implementation EMR-smart pump interoperability, medication library compliance improved significantly, rising from 93% to 97%, P<.0001. Alerts related to pump reprogramming and high-risk medications also increased, suggesting enhanced safety monitoring. At the same time, programming became more efficient, with the average number of keystrokes required dropping from 13±3.4 to 3±1.2, P<.0001. However, despite these gains, survey responses revealed a decline in clinician's perceived ease of use (from 90% to 45%, P<.0001) and confidence in programming (93% to 65%, P<.0001). While the rate of cancelled infusions alerts (20% vs. 14%, P<.0001) and all other nonspecific pump alerts (23% vs. 16%, P<.0001) reduced. The integration of EMR-smart pump interoperability enhances medication safety by increasing the frequency of clinical alerts and reducing manual data entry. However, this advancement may introduce usability challenges that impact staff confidence and workflow. These findings highlight the importance of balancing technological integration with user experience to optimize patient safety outcomes.

CIN Computers Informatics Nursing
La Trobe University (AU), Monash Health (AU)
Good health and well-being
Openalex Percentile: Top 27%
Patient Safety and Medication Errors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.