Influence of process parameters on shape fidelity in extrusion-based bioprinting: a rheological perspective

Extrusion-based bioprinting enables the controlled deposition of hydrogels, which are crucial for cell viability in bioengineering. In this context, shape fidelity—defined as the correspondence between the printed construct and its digital model—emerges as a critical performance metric. This study systematically investigates the influence of inlet pressure, printing speed, and temperature on shape fidelity for two hydrogels: a natural alginate/cellulose blend and a synthetic PEG-based material. Comprehensive rheological characterization was performed to assess viscoelastic behavior, and a Shape Fidelity Index (SFI) was applied to quantify dimensional accuracy across 24 parameter configurations. The synthetic hydrogel exhibited lower sensitivity to parameter variations, ensuring robust processability. Conversely, while the natural hydrogel was more sensitive to operating conditions, it achieved the highest absolute SFI values within the investigated experimental campaign. This superior performance is attributed to its distinct rheological behavior, characterized by a Sisko-type flow, which enhanced filament shape retention. These findings underscore the importance of integrated rheological analysis and parameter selection for improving the fabrication of high-resolution biomedical structures. Extrusion bioprinting enables precise deposition of hydrogel materials. Shape fidelity is key for matching prints to their digital models. Shape fidelity was studied for alginate/cellulose and PEG-based hydrogels. Synthetic hydrogel is more stable; natural one can exceed with tuning. Rheology and parameter tuning are crucial to improve bioprinting.

Authors

Institutions

Publication Details

Journal
The International Journal of Advanced Manufacturing Technology
Published
2026-03-17
DOI
https://doi.org/10.1007/s00170-026-17795-2
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of process parameters on shape fidelity in extrusion-based bioprinting: a rheological perspective

David Rodríguez Izquierdo, Domenico Gabriele, Carmine Borgia, Francesco Gagliardi
The International Journal of Advanced Manufacturing Technology
3D Printing in Biomedical Research
article

Influence of process parameters on shape fidelity in extrusion-based bioprinting: a rheological perspective

David Rodríguez Izquierdo, Domenico Gabriele, Carmine Borgia, Francesco Gagliardi
article en

Abstract

Extrusion-based bioprinting enables the controlled deposition of hydrogels, which are crucial for cell viability in bioengineering. In this context, shape fidelity—defined as the correspondence between the printed construct and its digital model—emerges as a critical performance metric. This study systematically investigates the influence of inlet pressure, printing speed, and temperature on shape fidelity for two hydrogels: a natural alginate/cellulose blend and a synthetic PEG-based material. Comprehensive rheological characterization was performed to assess viscoelastic behavior, and a Shape Fidelity Index (SFI) was applied to quantify dimensional accuracy across 24 parameter configurations. The synthetic hydrogel exhibited lower sensitivity to parameter variations, ensuring robust processability. Conversely, while the natural hydrogel was more sensitive to operating conditions, it achieved the highest absolute SFI values within the investigated experimental campaign. This superior performance is attributed to its distinct rheological behavior, characterized by a Sisko-type flow, which enhanced filament shape retention. These findings underscore the importance of integrated rheological analysis and parameter selection for improving the fabrication of high-resolution biomedical structures. Extrusion bioprinting enables precise deposition of hydrogel materials. Shape fidelity is key for matching prints to their digital models. Shape fidelity was studied for alginate/cellulose and PEG-based hydrogels. Synthetic hydrogel is more stable; natural one can exceed with tuning. Rheology and parameter tuning are crucial to improve bioprinting.

The International Journal of Advanced Manufacturing Technology
University of Calabria (IT)
Openalex Percentile: Top 19%
3D Printing in Biomedical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of process parameters on shape fidelity in extrusion-based bioprinting: a rheological perspective — David Rodríguez Izquierdo, Domenico Gabriele, et al. · The International Journal of Advanced Manufacturing Technology (2026) | TGRS Research Map | TGRS