Blood Loss Management in Total Knee Arthroplasty: Bipolar Sealer System vs. Fibrin Sealant: A New Fast-Track Protocol

Background/Objectives: Total knee arthroplasty (TKA) is often associated with extensive bleeding and the need for intraoperative and postoperative blood transfusions. Due to concern about the risks associated with them, a push has been made in surgery toward the development of new intraoperative blood management devices and innovative postoperative care strategies. Tranexamic acid (TXA), fibrin sealant and standard electrocautery are widely used in orthopedic surgery, since several studies provided evidence about their efficacy and safety. A new device, the bipolar sealer system (BSS), provides hemostasis at lower temperature (<100°) than conventional electrocautery. It does not produce smoke, necrosis or burn tissue. Methods: In this study, we retrospectively analyzed data from 480 patients who underwent TKA between January 2017 and December 2024. The cohort was divided into two groups based on the hemostatic protocol adopted. The control group enrolled 240 patients who received the standard protocol with TXA and fibrin sealant, while the study group enrolled 240 patients who followed protocol with Aquamantys BSS and TXA. Hematological parameters, including hemoglobin (Hb), hematocrit (HCT) and red blood cells (RBCs) were analyzed preoperatively (T0) and postoperatively: immediately after surgery (T1), at day one (T2) and day three (T3). Results: Changes in hemoglobin from baseline to postoperative follow-up were significantly lower among patients who received TXA plus BSS and those receiving TXA plus fibrin sealant, with p-values of 0.0003 at T1 (immediately after surgery), 0.027 at T2 (one day post-op), and 0.0001 at T3 (three days post-op). Comparable results were observed for HCT and RBC values. Conclusions: These data demonstrate that Aquamantys is more effective than fibrin glue in controlling blood loss after knee replacement surgery, not only immediately after the procedure but also in the following days.

Authors

Institutions

Publication Details

Journal
Prosthesis
Published
2026-03-17
DOI
https://doi.org/10.3390/prosthesis8030031
Primary Topic
Hemostasis and retained surgical items
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blood Loss Management in Total Knee Arthroplasty: Bipolar Sealer System vs. Fibrin Sealant: A New Fast-Track Protocol

Alessandro Geronimo, Giuseppe Danilo Cassano, Giuseppe Solarino, Antonio Spinarelli et al.
Prosthesis
Hemostasis and retained surgical items
article

Blood Loss Management in Total Knee Arthroplasty: Bipolar Sealer System vs. Fibrin Sealant: A New Fast-Track Protocol

Alessandro Geronimo, Giuseppe Danilo Cassano, Giuseppe Solarino, Antonio Spinarelli, Biagio Moretti, Lorenzo Moretti, Alessandro Scarpino, Elvira Ruggiero
article en

Abstract

Background/Objectives: Total knee arthroplasty (TKA) is often associated with extensive bleeding and the need for intraoperative and postoperative blood transfusions. Due to concern about the risks associated with them, a push has been made in surgery toward the development of new intraoperative blood management devices and innovative postoperative care strategies. Tranexamic acid (TXA), fibrin sealant and standard electrocautery are widely used in orthopedic surgery, since several studies provided evidence about their efficacy and safety. A new device, the bipolar sealer system (BSS), provides hemostasis at lower temperature (<100°) than conventional electrocautery. It does not produce smoke, necrosis or burn tissue. Methods: In this study, we retrospectively analyzed data from 480 patients who underwent TKA between January 2017 and December 2024. The cohort was divided into two groups based on the hemostatic protocol adopted. The control group enrolled 240 patients who received the standard protocol with TXA and fibrin sealant, while the study group enrolled 240 patients who followed protocol with Aquamantys BSS and TXA. Hematological parameters, including hemoglobin (Hb), hematocrit (HCT) and red blood cells (RBCs) were analyzed preoperatively (T0) and postoperatively: immediately after surgery (T1), at day one (T2) and day three (T3). Results: Changes in hemoglobin from baseline to postoperative follow-up were significantly lower among patients who received TXA plus BSS and those receiving TXA plus fibrin sealant, with p-values of 0.0003 at T1 (immediately after surgery), 0.027 at T2 (one day post-op), and 0.0001 at T3 (three days post-op). Comparable results were observed for HCT and RBC values. Conclusions: These data demonstrate that Aquamantys is more effective than fibrin glue in controlling blood loss after knee replacement surgery, not only immediately after the procedure but also in the following days.

ProsthesisVol. 8(3)
Ospedale degli Infermi (IT), University of Bari Aldo Moro (IT)
Good health and well-being
Openalex Percentile: Top 18%
Hemostasis and retained surgical items
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.