Cascaded Thermal Storage for Low-Carbon Heating: An Air-Assisted Ground-Source Heat Pump with Zoned Boreholes in a Cold-Climate Building

The pursuit of carbon neutrality demands advanced low-carbon energy processes and their effective integration into building systems. Ground-source heat pumps (GSHPs) offer a key pathway for decarbonizing heating, yet their cold-climate application is compromised by soil thermal imbalance, which degrades their long-term efficiency. This study proposes and evaluates an innovative air-assisted GSHP system that integrates a vegetable greenhouse with a zoned borehole configuration for seasonal thermal storage to achieve carbon neutrality. The system segregates boreholes into core and peripheral zones to establish a controlled soil temperature gradient, enabling cascaded heat storage and thermal optimization. A comprehensive year-long field test was conducted on a residential building in Harbin, China. The results demonstrate that the system reliably maintains comfortable indoor conditions during severe winters, achieving average seasonal COPs of 3.82 for the heat pump unit and 2.85 for the overall system. The zoned operation strategy successfully generated a significant intra-field soil temperature gradient, with a maximum differential of 5.9 °C between the core and peripheral boreholes during charging. The measured heat extraction-to-storage ratio was 0.598, confirming effective cascaded utilization. From an environmental perspective aligned with low-carbon energy technologies, the system achieves annual savings of 8.66 tons of standard coal and a net CO2 reduction of 1.3 tons when accounting for regional grid carbon intensity. This research provides empirical validation and practical design guidance for implementing efficient GSHP systems in severely cold regions, thereby contributing substantively to building sector decarbonization.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-03-17
DOI
https://doi.org/10.3390/pr14060958
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cascaded Thermal Storage for Low-Carbon Heating: An Air-Assisted Ground-Source Heat Pump with Zoned Boreholes in a Cold-Climate Building

Yongmin Liu, Peiqiang Chen, Zhuozhi Wang
Processes
Geothermal Energy Systems and Applications
article

Cascaded Thermal Storage for Low-Carbon Heating: An Air-Assisted Ground-Source Heat Pump with Zoned Boreholes in a Cold-Climate Building

Yongmin Liu, Peiqiang Chen, Zhuozhi Wang
article en

Abstract

The pursuit of carbon neutrality demands advanced low-carbon energy processes and their effective integration into building systems. Ground-source heat pumps (GSHPs) offer a key pathway for decarbonizing heating, yet their cold-climate application is compromised by soil thermal imbalance, which degrades their long-term efficiency. This study proposes and evaluates an innovative air-assisted GSHP system that integrates a vegetable greenhouse with a zoned borehole configuration for seasonal thermal storage to achieve carbon neutrality. The system segregates boreholes into core and peripheral zones to establish a controlled soil temperature gradient, enabling cascaded heat storage and thermal optimization. A comprehensive year-long field test was conducted on a residential building in Harbin, China. The results demonstrate that the system reliably maintains comfortable indoor conditions during severe winters, achieving average seasonal COPs of 3.82 for the heat pump unit and 2.85 for the overall system. The zoned operation strategy successfully generated a significant intra-field soil temperature gradient, with a maximum differential of 5.9 °C between the core and peripheral boreholes during charging. The measured heat extraction-to-storage ratio was 0.598, confirming effective cascaded utilization. From an environmental perspective aligned with low-carbon energy technologies, the system achieves annual savings of 8.66 tons of standard coal and a net CO2 reduction of 1.3 tons when accounting for regional grid carbon intensity. This research provides empirical validation and practical design guidance for implementing efficient GSHP systems in severely cold regions, thereby contributing substantively to building sector decarbonization.

ProcessesVol. 14(6)
Harbin Engineering University (CN), Hebei University of Technology (CN), East University Of Heilongjiang (CN)
Climate action
Openalex Percentile: Top 22%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.