Evolving Analytical Methods for the Quantification of Methocarbamol: A Critical Review

Methocarbamol (MT), a centrally acting muscle relaxant, presents significant analytical challenges due to its low ultraviolet (UV) absorptivity, rapid metabolism, and pronounced pH-dependent instability. The presence of guaifenesin-related impurities and interference from co-formulated analgesics further complicate its detection in pharmaceutical, biological, and environmental matrices. This review compiles peer-reviewed English-language studies indexed in Scopus, Web of Science, PubMed, ScienceDirect, and Google Scholar and provides a critical assessment of MT quantification methods developed over the past 25 years. Evidence shows that optimized high-performance liquid chromatography (HPLC), particularly fluorescence-based systems, provides the highest sensitivity and selectivity, achieving sub-ng/mL detection and overcoming limitations of UV assays, such as signal suppression and narrow linear ranges. Electrochemical approaches using CNT-, graphene-, MOF-, and magnetic-nanocomposite-modified electrodes enhance redox discrimination and enable nM-μM detection. Chemometric-assisted spectroscopic techniques offer rapid, low-cost analysis suitable for simple formulations but lack reliability in complex matrices. Across all platforms, strict pH control, rapid processing, and selective extraction methods-such as solid-phase extraction (SPE), molecularly imprinted polymer (MIP), and dispersive liquid-liquid microextraction (DLLME) remain essential to reduce degradation and matrix interference. Future progress will rely on miniaturized microfluidic systems, improved stability-indicating chromatography, and intelligent electrochemical sensors capable of multiplex quantification in challenging samples.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2026-03-17
DOI
https://doi.org/10.1002/bmc.70419
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evolving Analytical Methods for the Quantification of Methocarbamol: A Critical Review

Hemn A.H. Barzani, Seerwan Hamadameen Sulaiman, Amjad Mahmood Qadir, Nergz Bayiz Abdulrahman et al.
Biomedical Chromatography
Analytical chemistry methods development
article

Evolving Analytical Methods for the Quantification of Methocarbamol: A Critical Review

Hemn A.H. Barzani, Seerwan Hamadameen Sulaiman, Amjad Mahmood Qadir, Nergz Bayiz Abdulrahman, Rebaz Anwar Omer
article en

Abstract

Methocarbamol (MT), a centrally acting muscle relaxant, presents significant analytical challenges due to its low ultraviolet (UV) absorptivity, rapid metabolism, and pronounced pH-dependent instability. The presence of guaifenesin-related impurities and interference from co-formulated analgesics further complicate its detection in pharmaceutical, biological, and environmental matrices. This review compiles peer-reviewed English-language studies indexed in Scopus, Web of Science, PubMed, ScienceDirect, and Google Scholar and provides a critical assessment of MT quantification methods developed over the past 25 years. Evidence shows that optimized high-performance liquid chromatography (HPLC), particularly fluorescence-based systems, provides the highest sensitivity and selectivity, achieving sub-ng/mL detection and overcoming limitations of UV assays, such as signal suppression and narrow linear ranges. Electrochemical approaches using CNT-, graphene-, MOF-, and magnetic-nanocomposite-modified electrodes enhance redox discrimination and enable nM-μM detection. Chemometric-assisted spectroscopic techniques offer rapid, low-cost analysis suitable for simple formulations but lack reliability in complex matrices. Across all platforms, strict pH control, rapid processing, and selective extraction methods-such as solid-phase extraction (SPE), molecularly imprinted polymer (MIP), and dispersive liquid-liquid microextraction (DLLME) remain essential to reduce degradation and matrix interference. Future progress will rely on miniaturized microfluidic systems, improved stability-indicating chromatography, and intelligent electrochemical sensors capable of multiplex quantification in challenging samples.

Biomedical ChromatographyVol. 40(5)
University of Halabja (IQ), Sulaimani Polytechnic University (IQ), Lebanese French University (IQ), Koya University (IQ)
Peace, Justice and strong institutions
Openalex Percentile: Top 17%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines