Detecting Condylar Lift-Off with a Piezoelectric Smart Knee Replacement

Smart knee replacement technology seeks to provide an in vivo method of tracking long-term postoperative joint loads with the goal of identifying clinically relevant phenomena linked to postoperative dissatisfaction in real time. This study evaluated the ability of a piezoelectric compartmental force and compartmental center of pressure sensing total knee replacement to sense condylar lift-off, which is a clinically relevant phenomenon commonly attributed to postoperative dissatisfaction. A commercially available total knee replacement was modified to include six piezoelectric transducers capable of measuring compartmental forces and tibiofemoral centers of pressure on the articular surface of the tibial bearing insert. The smart knee replacement was evaluated with a six-degree-of-freedom joint motion simulator applying a varus lift-off profile. The study demonstrated that the lift-off was evident in both the sensed joint loads and the localized tibiofemoral centers of pressure obtained from the piezoelectric sensing system. The results indicated that the piezoelectric smart knee replacement could be effective for detecting this clinically problematic mechanical issue.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-03-17
DOI
https://doi.org/10.3390/bioengineering13030346
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detecting Condylar Lift-Off with a Piezoelectric Smart Knee Replacement

Brandon D. Hines, Ryan Willing, Steven R. Anton
Bioengineering
Total Knee Arthroplasty Outcomes
article

Detecting Condylar Lift-Off with a Piezoelectric Smart Knee Replacement

Brandon D. Hines, Ryan Willing, Steven R. Anton
article en

Abstract

Smart knee replacement technology seeks to provide an in vivo method of tracking long-term postoperative joint loads with the goal of identifying clinically relevant phenomena linked to postoperative dissatisfaction in real time. This study evaluated the ability of a piezoelectric compartmental force and compartmental center of pressure sensing total knee replacement to sense condylar lift-off, which is a clinically relevant phenomenon commonly attributed to postoperative dissatisfaction. A commercially available total knee replacement was modified to include six piezoelectric transducers capable of measuring compartmental forces and tibiofemoral centers of pressure on the articular surface of the tibial bearing insert. The smart knee replacement was evaluated with a six-degree-of-freedom joint motion simulator applying a varus lift-off profile. The study demonstrated that the lift-off was evident in both the sensed joint loads and the localized tibiofemoral centers of pressure obtained from the piezoelectric sensing system. The results indicated that the piezoelectric smart knee replacement could be effective for detecting this clinically problematic mechanical issue.

BioengineeringVol. 13(3)
Western University (CA), Tennessee Technological University (US)
Openalex Percentile: Top 20%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.