Real-time ultrasound guidance increases ropivacaine requirement for combined spinal–epidural anesthesia in cesarean delivery compared to landmark technique: a dose-finding study

Whether real-time ultrasound guidance changes the minimum local anesthetic dose (MLAD/ED50) of intrathecal ropivacaine with dexmedetomidine for cesarean delivery under combined spinal–epidural anesthesia (CSEA) remains unclear. We compared MLAD between ultrasound-guided and landmark-guided CSEA. In this randomized trial, 60 parturients undergoing elective cesarean delivery received CSEA at the L3–4 interspace with intrathecal ropivacaine plus dexmedetomidine 5 µg (ultrasound-guided, n = 30; landmark-guided, n = 30). MLAD was estimated using the Dixon up-and-down method (starting dose 10 mg; step size 0.5 mg). Hemodynamics, block characteristics, adverse events, intraoperative VAS scores, and neonatal Apgar scores were assessed as secondary outcomes. Baseline characteristics were similar. MLAD was higher with ultrasound guidance than with landmark guidance (10.14 mg [95% CI 9.87–10.41] vs 9.09 mg [95% CI 8.74–9.45]; p = 0.002), confirmed by probit regression (p = 0.004). Compared to baseline values at T0, both systolic and diastolic blood pressure decreased in both groups; however, the reduction at 5 min after injection was smaller in the ultrasound-guided group than in the landmark-guided group. Sensory/motor block profiles, adverse events, intraoperative VAS scores, and Apgar scores were comparable between groups. When performing ultrasound-guided CSEA at L3–4 for cesarean delivery, clinicians should anticipate a modestly higher intrathecal ropivacaine requirement than with the landmark technique. Both approaches provide comparable anesthesia quality and maternal–neonatal safety; therefore, intrathecal ropivacaine dosing recommendations should be technique-specific. ChiCTR2200058312

Authors

Institutions

Publication Details

Journal
European journal of medical research
Published
2026-03-16
DOI
https://doi.org/10.1186/s40001-026-04137-x
Primary Topic
Anesthesia and Pain Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time ultrasound guidance increases ropivacaine requirement for combined spinal–epidural anesthesia in cesarean delivery compared to landmark technique: a dose-finding study

Yagui Liang, Digui Weng, Xialing Lian, Chai Lin et al.
European journal of medical research
Anesthesia and Pain Management
article

Real-time ultrasound guidance increases ropivacaine requirement for combined spinal–epidural anesthesia in cesarean delivery compared to landmark technique: a dose-finding study

Yagui Liang, Digui Weng, Xialing Lian, Chai Lin, Zhangjian Chen, Qingqing Huang
article en

Abstract

Whether real-time ultrasound guidance changes the minimum local anesthetic dose (MLAD/ED50) of intrathecal ropivacaine with dexmedetomidine for cesarean delivery under combined spinal–epidural anesthesia (CSEA) remains unclear. We compared MLAD between ultrasound-guided and landmark-guided CSEA. In this randomized trial, 60 parturients undergoing elective cesarean delivery received CSEA at the L3–4 interspace with intrathecal ropivacaine plus dexmedetomidine 5 µg (ultrasound-guided, n = 30; landmark-guided, n = 30). MLAD was estimated using the Dixon up-and-down method (starting dose 10 mg; step size 0.5 mg). Hemodynamics, block characteristics, adverse events, intraoperative VAS scores, and neonatal Apgar scores were assessed as secondary outcomes. Baseline characteristics were similar. MLAD was higher with ultrasound guidance than with landmark guidance (10.14 mg [95% CI 9.87–10.41] vs 9.09 mg [95% CI 8.74–9.45]; p = 0.002), confirmed by probit regression (p = 0.004). Compared to baseline values at T0, both systolic and diastolic blood pressure decreased in both groups; however, the reduction at 5 min after injection was smaller in the ultrasound-guided group than in the landmark-guided group. Sensory/motor block profiles, adverse events, intraoperative VAS scores, and Apgar scores were comparable between groups. When performing ultrasound-guided CSEA at L3–4 for cesarean delivery, clinicians should anticipate a modestly higher intrathecal ropivacaine requirement than with the landmark technique. Both approaches provide comparable anesthesia quality and maternal–neonatal safety; therefore, intrathecal ropivacaine dosing recommendations should be technique-specific. ChiCTR2200058312

European journal of medical research
Fujian Medical University (CN), First Affiliated Hospital of Fujian Medical University (CN), Union Hospital (CN)
Good health and well-being
Openalex Percentile: Top 20%
Anesthesia and Pain Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.