Low Cost Monitoring System of Ground Reaction Force during Normal Gait Cycle for Motion Control and Analysis of Active Ankle Foot Orthosis

Human gaits are complicated motion where it involves synergy of muscle coordination, timing, and balance. Many people are unable to walk with normal gait pattern due to neuromuscular disorder. In order to support the weakness muscle, Active Ankle Foot Orthosis (AAFO) device is developed to provide permanent assistance and control the motion of the foot from being dragged during walking. One of the challenges that researchers has to face with the development of AAFO is providing an efficient transmission and producing continuous and smooth gait cycle. This paper proposes a real time gait phase detection system to control AAFO for rehabilitation and assist ankle motion. Real-time gait phase is obtained by measuring ground reaction force (GRF). The proposed system consists of AAFO equipped with ball screw actuator that provides direct assistance to control ankle joint during dorsiflexion and plantarflexion motion. Three force sensors were embedded insole and an encoder was attached at the ankle joint. The developed control algorithm shows that the real-time GRF measurement has the ability to enhance the AAFO functional performance and improve patient’s gait.

Authors

Publication Details

Journal
International Journal of Engineering & Technology
Published
2026-03-15
DOI
https://doi.org/10.14419/ijet.v7i4.26.28568
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low Cost Monitoring System of Ground Reaction Force during Normal Gait Cycle for Motion Control and Analysis of Active Ankle Foot Orthosis

Hokyoo Lee, Aminuddin Hamid, Azim Patar, Muhammad Azmi Ayub et al.
International Journal of Engineering & Technology
Prosthetics and Rehabilitation Robotics
article

Low Cost Monitoring System of Ground Reaction Force during Normal Gait Cycle for Motion Control and Analysis of Active Ankle Foot Orthosis

Hokyoo Lee, Aminuddin Hamid, Azim Patar, Muhammad Azmi Ayub, Mohd Nor Azmi Ab Patar
article en

Abstract

Human gaits are complicated motion where it involves synergy of muscle coordination, timing, and balance. Many people are unable to walk with normal gait pattern due to neuromuscular disorder. In order to support the weakness muscle, Active Ankle Foot Orthosis (AAFO) device is developed to provide permanent assistance and control the motion of the foot from being dragged during walking. One of the challenges that researchers has to face with the development of AAFO is providing an efficient transmission and producing continuous and smooth gait cycle. This paper proposes a real time gait phase detection system to control AAFO for rehabilitation and assist ankle motion. Real-time gait phase is obtained by measuring ground reaction force (GRF). The proposed system consists of AAFO equipped with ball screw actuator that provides direct assistance to control ankle joint during dorsiflexion and plantarflexion motion. Three force sensors were embedded insole and an encoder was attached at the ankle joint. The developed control algorithm shows that the real-time GRF measurement has the ability to enhance the AAFO functional performance and improve patient’s gait.

International Journal of Engineering & TechnologyVol. 7(4.26)
Good health and well-being
Openalex Percentile: Top 20%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.