Method development and validation for estimation of capsaicin in topical formulations by gas chromatography

This study presents, a novel, simple, rapid, and highly sensitive Gas Chromatography–Flame Ionization Detection (GC-FID) method developed for capsaicin estimation in marketed semi-solid topical analgesic formulations and validated according to ICH Q2 (R1). Capsaicin, an alkaloid of Capsicum species shows its analgesic effect through selective activation of the transient receptor potential vanilloid 1 (TRPV1) channel on nociceptive neurons. Sustained stimulation leads to desensitization and depletion of neuropeptides, resulting in attenuation of pain signalling. Accurate quantification of capsaicin in topical formulations is essential to ensure therapeutic consistency, especially in semi-solid matrices that contain multiple co-actives and potential analytical interferents. Although GC-based methods have been reported for capsaicin in food matrices and multi-component topical analyses, no rapid, dedicated GC-FID method has been described for selective quantification of capsaicin in commercial balm and gel formulations using conventional instrumentation. Chromatographic separation using an HP-5 capillary column yielded a sharp, well-resolved capsaicin peak having a tailing factor of 1.21, with a total run time 9.5 min. The method demonstrated excellent specificity, with no matrix interference, and exhibited linearity across 50–1000 µg/mL (R² = 1.000). The method has high sensitivity, with LOD of 7.2 µg/ml and LOQ of 21.8 µg/ml. Assay of commercial topical balm and gel formulation reveals a concentration of 0.015% to 0.018%. The proposed GC-FID method minimizes matrix interference, simplifies sample preparation, and enables rapid, cost effective analysis with a short run time, making it suitable for routine quality control and stability assessment of capsaicin-containing topical formulations.

Authors

Institutions

Publication Details

Journal
Discover Chemistry.
Published
2026-03-16
DOI
https://doi.org/10.1007/s44371-026-00590-z
Primary Topic
Ion Channels and Receptors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method development and validation for estimation of capsaicin in topical formulations by gas chromatography

Sagar Maiti, Punita Kalra, Subhadeep Chowdhury, Fahmida Faizah et al.
Discover Chemistry.
Ion Channels and Receptors
article

Method development and validation for estimation of capsaicin in topical formulations by gas chromatography

Sagar Maiti, Punita Kalra, Subhadeep Chowdhury, Fahmida Faizah, Rahul Singh, Partha Ganguly
article en

Abstract

This study presents, a novel, simple, rapid, and highly sensitive Gas Chromatography–Flame Ionization Detection (GC-FID) method developed for capsaicin estimation in marketed semi-solid topical analgesic formulations and validated according to ICH Q2 (R1). Capsaicin, an alkaloid of Capsicum species shows its analgesic effect through selective activation of the transient receptor potential vanilloid 1 (TRPV1) channel on nociceptive neurons. Sustained stimulation leads to desensitization and depletion of neuropeptides, resulting in attenuation of pain signalling. Accurate quantification of capsaicin in topical formulations is essential to ensure therapeutic consistency, especially in semi-solid matrices that contain multiple co-actives and potential analytical interferents. Although GC-based methods have been reported for capsaicin in food matrices and multi-component topical analyses, no rapid, dedicated GC-FID method has been described for selective quantification of capsaicin in commercial balm and gel formulations using conventional instrumentation. Chromatographic separation using an HP-5 capillary column yielded a sharp, well-resolved capsaicin peak having a tailing factor of 1.21, with a total run time 9.5 min. The method demonstrated excellent specificity, with no matrix interference, and exhibited linearity across 50–1000 µg/mL (R² = 1.000). The method has high sensitivity, with LOD of 7.2 µg/ml and LOQ of 21.8 µg/ml. Assay of commercial topical balm and gel formulation reveals a concentration of 0.015% to 0.018%. The proposed GC-FID method minimizes matrix interference, simplifies sample preparation, and enables rapid, cost effective analysis with a short run time, making it suitable for routine quality control and stability assessment of capsaicin-containing topical formulations.

Discover Chemistry.Vol. 3(1)
Emami (India) (IN)
Openalex Percentile: Top 18%
Ion Channels and Receptors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.