Resilient sampled-data dynamic output feedback control of Takagi–Sugeno fuzzy systems under denial-of-service attacks
This paper investigates the problem of dynamic output feedback control for Takagi–Sugeno (T-S) fuzzy systems under denial-of-service (DoS) attacks. First, a resilient sampled-data method is designed to resist the effect of DoS attacks. Then, a maximum DoS attack rate is proposed to evaluate the system resistance to attacks. Next, a cooperative framework is used to describe T-S fuzzy model, resilient sampling mechanisms, and DoS attacks. By using the interval property of resilient sampling, the associated Lyapunov function is constructed and the stability of the T-S fuzzy system is proved by combining inequality and convex combination techniques. In addition, a linear matrix inequality technique is utilized to find controller gains. Finally, a numerical simulation verifies the correctness of that proposed control strategy.
Authors
- Di Lun
- Nan Zhao (ORCID: https://orcid.org/0000-0002-7897-2374)
- Sheng Peng (ORCID: https://orcid.org/0000-0002-0224-1815)
- Dongke Zhao (ORCID: https://orcid.org/0009-0008-7357-3615)
Institutions
- Bohai University (CN)
Publication Details
- Journal
- Transactions of the Institute of Measurement and Control
- Published
- 2026-03-15
- DOI
- https://doi.org/10.1177/01423312261425205
- Primary Topic
- Smart Grid Security and Resilience
- Type
- article
- Field-Weighted Citation Impact
- 0.00