Clinical Outcomes of Robotic-Assisted Gynecologic Surgery: A Single-Center 70-Case Series Experience

Background Robotic-assisted surgery has emerged as an advanced minimally invasive approach in gynecology, offering enhanced visualization, precision, and ergonomics. However, real-world clinical data from Indian centers, particularly using indigenously developed robotic platforms, remain limited. Objective This study aims to evaluate the spectrum of indications, perioperative outcomes, and robotic-assisted gynecologic procedures performed with the SSI Mantra 3 Surgical Robotic System (SS Innovations International Inc., Gurugram, India) at a tertiary care center in India. Methods This retrospective case series included 70 consecutive patients who underwent robotic-assisted gynecologic surgery between August and December 2025. Procedures were performed using the SSI Mantra™ robotic system and included robotic hysterectomy (RH), robotic myomectomy (RM), and robotic cystectomy (RC) for benign gynecologic indications. Demographic variables, operative parameters (operative time, docking time, console time), estimated blood loss, length of hospital stay, and perioperative complications were analyzed using descriptive statistics. Results Of the 70 procedures, RH was the most common (31 cases, 44%), followed by RC (20 cases, 29%) and RM (19 cases, 27%). Patients undergoing RH were older than those in RM and RC, while body mass index was comparable across groups. RC demonstrated the shortest operative time (60.3 ± 18.5 minutes), lowest estimated blood loss (28.3 ± 39.6 mL), and shortest hospital stay (2.3 ± 0.8 days). RH had the longest operative time (119.3 ± 44.0 minutes) but remained associated with acceptable blood loss (113.8 ± 66.9 mL) and short hospitalization (2.7 ± 0.8 days). No intraoperative or postoperative complications were observed in any group. Conclusion Robotic-assisted gynecologic surgery using the SSI Mantra™ system is safe, feasible, and effective across a broad range of benign gynecologic conditions. The favorable perioperative outcomes, minimal blood loss, short hospital stay, and absence of complications support the integration of this indigenous robotic platform into contemporary minimally invasive gynecologic practice in India.

Authors

Publication Details

Journal
Cureus
Published
2026-03-16
DOI
https://doi.org/10.7759/cureus.105309
Primary Topic
Endometrial and Cervical Cancer Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Outcomes of Robotic-Assisted Gynecologic Surgery: A Single-Center 70-Case Series Experience

Neetu Mehta, Mrinal Chatterjee, Rahul Gour, Sonal Jain et al.
Cureus
Endometrial and Cervical Cancer Treatments
article

Clinical Outcomes of Robotic-Assisted Gynecologic Surgery: A Single-Center 70-Case Series Experience

Neetu Mehta, Mrinal Chatterjee, Rahul Gour, Sonal Jain, Kamal Uddin Zaidi, Priya Bhave, Madhuri Brahmne, Narendra Thakur
article en

Abstract

Background Robotic-assisted surgery has emerged as an advanced minimally invasive approach in gynecology, offering enhanced visualization, precision, and ergonomics. However, real-world clinical data from Indian centers, particularly using indigenously developed robotic platforms, remain limited. Objective This study aims to evaluate the spectrum of indications, perioperative outcomes, and robotic-assisted gynecologic procedures performed with the SSI Mantra 3 Surgical Robotic System (SS Innovations International Inc., Gurugram, India) at a tertiary care center in India. Methods This retrospective case series included 70 consecutive patients who underwent robotic-assisted gynecologic surgery between August and December 2025. Procedures were performed using the SSI Mantra™ robotic system and included robotic hysterectomy (RH), robotic myomectomy (RM), and robotic cystectomy (RC) for benign gynecologic indications. Demographic variables, operative parameters (operative time, docking time, console time), estimated blood loss, length of hospital stay, and perioperative complications were analyzed using descriptive statistics. Results Of the 70 procedures, RH was the most common (31 cases, 44%), followed by RC (20 cases, 29%) and RM (19 cases, 27%). Patients undergoing RH were older than those in RM and RC, while body mass index was comparable across groups. RC demonstrated the shortest operative time (60.3 ± 18.5 minutes), lowest estimated blood loss (28.3 ± 39.6 mL), and shortest hospital stay (2.3 ± 0.8 days). RH had the longest operative time (119.3 ± 44.0 minutes) but remained associated with acceptable blood loss (113.8 ± 66.9 mL) and short hospitalization (2.7 ± 0.8 days). No intraoperative or postoperative complications were observed in any group. Conclusion Robotic-assisted gynecologic surgery using the SSI Mantra™ system is safe, feasible, and effective across a broad range of benign gynecologic conditions. The favorable perioperative outcomes, minimal blood loss, short hospital stay, and absence of complications support the integration of this indigenous robotic platform into contemporary minimally invasive gynecologic practice in India.

Cureus
Openalex Percentile: Top 19%
Endometrial and Cervical Cancer Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.