Experimental Investigation of a Tubular Front Cavity for Wind Noise Suppression in MEMS Microphones of Mobile Devices

Wind-induced noise remains a critical engineering challenge for MEMS microphones in compact consumer electronics such as smartphones, where spatial constraints limit conventional noise control solutions. This study experimentally investigates the suppression of flow-induced wind noise by a straight tube serving as the front cavity of a microphone, using a precision measurement microphone for data acquisition. Controlled experiments were conducted in both a flow duct for parametric isolation and an anechoic chamber for real-world validation. Results demonstrate a strong diameter-dependent effect: for a 1 mm diameter, increasing tube length significantly reduces noise power spectral density and steepens high-frequency roll-off via enhanced internal viscous and thermal dissipation. This effect weakens for a 2 mm diameter and becomes negligible for a 3 mm diameter, where noise is dominated by external flow excitation at the tube inlet rather than internal propagation. Therefore, extending tube length is an effective noise control strategy only for small-diameter cavities. Furthermore, while increased wind speed and oblique incidence elevate PSD, a longer tube reduces this sensitivity. Because acoustic transmission loss-including potential effects like aperture diffraction and impedance mismatch-was not measured, any resulting improvement in the effective signal-to-noise ratio is strictly presented as a hypothesis requiring future electroacoustic validation. The consistent findings across both experimental environments provide clear design guidance: for compact MEMS microphone systems in portable devices, elongating the front cavity is a viable passive noise control method only when the cavity diameter is sufficiently small (<2 mm). This offers a practical, space-efficient alternative to traditional windscreen-based approaches in portable devices.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2026-03-14
DOI
https://doi.org/10.3390/mi17030357
Primary Topic
Aerodynamics and Acoustics in Jet Flows
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of a Tubular Front Cavity for Wind Noise Suppression in MEMS Microphones of Mobile Devices

Shiyu Wei, Bilong Liu, Chengpu Sun
Micromachines
Aerodynamics and Acoustics in Jet Flows
article

Experimental Investigation of a Tubular Front Cavity for Wind Noise Suppression in MEMS Microphones of Mobile Devices

Shiyu Wei, Bilong Liu, Chengpu Sun
article en

Abstract

Wind-induced noise remains a critical engineering challenge for MEMS microphones in compact consumer electronics such as smartphones, where spatial constraints limit conventional noise control solutions. This study experimentally investigates the suppression of flow-induced wind noise by a straight tube serving as the front cavity of a microphone, using a precision measurement microphone for data acquisition. Controlled experiments were conducted in both a flow duct for parametric isolation and an anechoic chamber for real-world validation. Results demonstrate a strong diameter-dependent effect: for a 1 mm diameter, increasing tube length significantly reduces noise power spectral density and steepens high-frequency roll-off via enhanced internal viscous and thermal dissipation. This effect weakens for a 2 mm diameter and becomes negligible for a 3 mm diameter, where noise is dominated by external flow excitation at the tube inlet rather than internal propagation. Therefore, extending tube length is an effective noise control strategy only for small-diameter cavities. Furthermore, while increased wind speed and oblique incidence elevate PSD, a longer tube reduces this sensitivity. Because acoustic transmission loss-including potential effects like aperture diffraction and impedance mismatch-was not measured, any resulting improvement in the effective signal-to-noise ratio is strictly presented as a hypothesis requiring future electroacoustic validation. The consistent findings across both experimental environments provide clear design guidance: for compact MEMS microphone systems in portable devices, elongating the front cavity is a viable passive noise control method only when the cavity diameter is sufficiently small (<2 mm). This offers a practical, space-efficient alternative to traditional windscreen-based approaches in portable devices.

MicromachinesVol. 17(3)
Qingdao University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 18%
Aerodynamics and Acoustics in Jet Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.