EVALUATION OF THE DIAGNOSTIC PERFORMANCE OF THE HEMOSPARK+ HEMOGLOBIN METER: A COMPARATIVE ANALYSIS AGAINST THE MINDRAY BC760 FULLY AUTOMATED HEMATOLOGY ANALYZER REFERENCE STANDARD

Background: Given that Hemoglobin (Hb) is the vital respiratory protein responsible for oxygen transport and carbon dioxide removal, its accurate estimation remains a cornerstone of diagnostic blood analysis and anemia screening. While laboratory-based Automated Hematology Analyzers remain the gold standard, the increasing need for point-of-care testing by healthcare personnel necessitates the use of portable meters. This study evaluates the diagnostic accuracy and clinical reliability of the HemoSpark+ Hemoglobin meter in comparison to automated analyzers to determine its efficacy for both clinical and bedside monitoring. Objective: To evaluate the diagnostic accuracy of the HemoSpark+ Hemoglobin meter, hemoglobin levels were estimated in parallel with an Mindray BC760 Fully Automated hematology analyzer within a NABL-accredited laboratory environment. Materials and Methods: To determine the diagnostic correlation for anemia classification, hemoglobin levels were estimated simultaneously using the HemoSpark+ meter and an Mindray BC760 Fully Automated hematology analyzer. The study utilized 631 samples (565 adults and 66 pediatric cases) processed in a NABL-accredited facility between September 2025 and December 2025, ensuring sample integrity through standardized equipment-aided mixing protocols prior to analysis. Results: Comparative analysis confirmed the HemoSpark+ reliability against the Mindray BC760 Fully Automated hematology analyzer reference standard; The linear regression analysis shows an exceptional correlation between the two methods,the study recorded a strong r2 value of 0.985. The 95% LOA were narrow, ranging from -0.230 to +0.259 g/dL. It also has a negligible positive bias of +0.015 g/dL, indicating no systematic overestimation or underestimation by the HemoSpark+ meter. Conclusion: This study concludes that the HemoSpark+ digital hemoglobin meter demonstrates high analytical parity with the Mindray BC760 Fully Automated Hematology Analyzer reference standard. Given its strong statistical agreement and cost-efficiency relative to traditional hematology analyzers, the HemoSpark+ is highly suitable for point-of-care applications, particularly where rapid, isolated hemoglobin estimation is required.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-03-16
DOI
https://doi.org/10.5281/zenodo.19046992
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF THE DIAGNOSTIC PERFORMANCE OF THE HEMOSPARK+ HEMOGLOBIN METER: A COMPARATIVE ANALYSIS AGAINST THE MINDRAY BC760 FULLY AUTOMATED HEMATOLOGY ANALYZER REFERENCE STANDARD

M. Bindu*1, N Akshitha2, Praveena3
Zenodo (CERN European Organization for Nuclear Research)
Clinical Laboratory Practices and Quality Control
article

EVALUATION OF THE DIAGNOSTIC PERFORMANCE OF THE HEMOSPARK+ HEMOGLOBIN METER: A COMPARATIVE ANALYSIS AGAINST THE MINDRAY BC760 FULLY AUTOMATED HEMATOLOGY ANALYZER REFERENCE STANDARD

M. Bindu*1, N Akshitha2, Praveena3
article en

Abstract

Background: Given that Hemoglobin (Hb) is the vital respiratory protein responsible for oxygen transport and carbon dioxide removal, its accurate estimation remains a cornerstone of diagnostic blood analysis and anemia screening. While laboratory-based Automated Hematology Analyzers remain the gold standard, the increasing need for point-of-care testing by healthcare personnel necessitates the use of portable meters. This study evaluates the diagnostic accuracy and clinical reliability of the HemoSpark+ Hemoglobin meter in comparison to automated analyzers to determine its efficacy for both clinical and bedside monitoring. Objective: To evaluate the diagnostic accuracy of the HemoSpark+ Hemoglobin meter, hemoglobin levels were estimated in parallel with an Mindray BC760 Fully Automated hematology analyzer within a NABL-accredited laboratory environment. Materials and Methods: To determine the diagnostic correlation for anemia classification, hemoglobin levels were estimated simultaneously using the HemoSpark+ meter and an Mindray BC760 Fully Automated hematology analyzer. The study utilized 631 samples (565 adults and 66 pediatric cases) processed in a NABL-accredited facility between September 2025 and December 2025, ensuring sample integrity through standardized equipment-aided mixing protocols prior to analysis. Results: Comparative analysis confirmed the HemoSpark+ reliability against the Mindray BC760 Fully Automated hematology analyzer reference standard; The linear regression analysis shows an exceptional correlation between the two methods,the study recorded a strong r2 value of 0.985. The 95% LOA were narrow, ranging from -0.230 to +0.259 g/dL. It also has a negligible positive bias of +0.015 g/dL, indicating no systematic overestimation or underestimation by the HemoSpark+ meter. Conclusion: This study concludes that the HemoSpark+ digital hemoglobin meter demonstrates high analytical parity with the Mindray BC760 Fully Automated Hematology Analyzer reference standard. Given its strong statistical agreement and cost-efficiency relative to traditional hematology analyzers, the HemoSpark+ is highly suitable for point-of-care applications, particularly where rapid, isolated hemoglobin estimation is required.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 20%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EVALUATION OF THE DIAGNOSTIC PERFORMANCE OF THE HEMOSPARK+ HEMOGLOBIN METER: A COMPARATIVE ANALYSIS AGAINST THE MINDRAY BC760 FULLY AUTOMATED HEMATOLOGY ANALYZER REFERENCE STANDARD — M. Bindu*1, N Akshitha2, Praveena3 · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS