Smartphone-assisted lateral flow nanosensor for the selective detection of GHB in urine

We report a rapid test strip based on mesoporous silica nanoparticles functionalized with a specific GABA<sub>B</sub> receptor agonist to selectively detect γ-hydroxybutyric acid (GHB) in urine samples. The sensing mechanism involves rhodamine B-loaded MCM-41 silica nanoparticles whose pores are capped with a GABA-derived ligand (baclofen) acting as a gatekeeper via supramolecular interactions with the GABA<sub>B</sub> receptor protein. In the presence of GHB, competitive binding produces GABA<sub>B</sub> receptor protein displacement, leading to pore opening and fluorophore release, which is detected via fluorescence readout. The nanosensor demonstrated high sensitivity, with a limit of detection (LOD) of 168 μM in buffer solution and 41 μM in diluted urine. Selectivity assays showed highly specific sensor response over common drugs such as cocaine, morphine, MDMA, heroin, scopolamine, 1,4-butenediol (1,4-BD), γ-aminobutyric acid (GABA), and γ-butyrolactone (GBL). The sensing material was also incorporated into a lateral flow assay (LFA) platform with a smartphone-assisted fluorescence readout, providing a rapid, portable, and low-cost analysis of GHB. The resulting test strip exhibited high sensitivity, with a LOD of 0.28 μM in diluted urine, which is low enough to clearly distinguish between physiological endogenous GHB levels (∼96 μM) and exogenous intake within only 1 min, a crucial requirement in forensic and clinical toxicology. This portable, cost-effective method holds strong potential for on-site forensic and clinical GHB screening.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2026-03-16
DOI
https://doi.org/10.1016/j.bios.2026.118628
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartphone-assisted lateral flow nanosensor for the selective detection of GHB in urine

Estela Climent, Guillermo Hernández-Sigüenza, Lara Mollà-Guerola, Eduardo Ortiz-Gómez et al.
Biosensors and Bioelectronics
Forensic Toxicology and Drug Analysis
article

Smartphone-assisted lateral flow nanosensor for the selective detection of GHB in urine

Estela Climent, Guillermo Hernández-Sigüenza, Lara Mollà-Guerola, Eduardo Ortiz-Gómez, Rocío López-Lima, Eva María Nieto Garrido, Andy Hernández-Montoto, Vicente Martí-Centelles, Pablo Gaviña, Giovanni Montà-González, Ramón Martínez-Máñez
article en

Abstract

We report a rapid test strip based on mesoporous silica nanoparticles functionalized with a specific GABA<sub>B</sub> receptor agonist to selectively detect γ-hydroxybutyric acid (GHB) in urine samples. The sensing mechanism involves rhodamine B-loaded MCM-41 silica nanoparticles whose pores are capped with a GABA-derived ligand (baclofen) acting as a gatekeeper via supramolecular interactions with the GABA<sub>B</sub> receptor protein. In the presence of GHB, competitive binding produces GABA<sub>B</sub> receptor protein displacement, leading to pore opening and fluorophore release, which is detected via fluorescence readout. The nanosensor demonstrated high sensitivity, with a limit of detection (LOD) of 168 μM in buffer solution and 41 μM in diluted urine. Selectivity assays showed highly specific sensor response over common drugs such as cocaine, morphine, MDMA, heroin, scopolamine, 1,4-butenediol (1,4-BD), γ-aminobutyric acid (GABA), and γ-butyrolactone (GBL). The sensing material was also incorporated into a lateral flow assay (LFA) platform with a smartphone-assisted fluorescence readout, providing a rapid, portable, and low-cost analysis of GHB. The resulting test strip exhibited high sensitivity, with a LOD of 0.28 μM in diluted urine, which is low enough to clearly distinguish between physiological endogenous GHB levels (∼96 μM) and exogenous intake within only 1 min, a crucial requirement in forensic and clinical toxicology. This portable, cost-effective method holds strong potential for on-site forensic and clinical GHB screening.

Biosensors and BioelectronicsVol. 304
Instituto de Investigación Sanitaria La Fe (ES), Universitat Politècnica de València (ES)
Good health and well-being
Openalex Percentile: Top 18%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.