Digital Recordings of Centric Relation Using Conventional and Digital Techniques: Patient-Reported Outcome Measures (PROMs)

<b>Background/Objectives:</b> Centric relation (CR) is a reproducible mandibular reference position that plays a critical role in complex prosthodontic cases. With the advent of digital jaw-tracking devices, CR can now be recorded with greater precision through fully digital methods. This study aimed to compare patient-reported outcome measures (PROMs) for the recording of CR determined with conventional and digital techniques. <b>Methods:</b> Patients requiring occlusal rehabilitation due to bilateral loss of posterior support in the maxilla were included. Two different jaw relation recording techniques were applied: conventionally determined CR and digitally determined CR. The former was determined using bimanual manipulation, while the latter through multiple mandibular closure recordings performed with an anterior plateau using a jaw-tracking device. PROMs were assessed using Visual Analog Scale (VAS) to evaluate patient experience during jaw relation recording and comfort during restoration try-in. The recording time for both techniques was documented, and the correlation between recording time and VAS scores related to the recording procedure was analyzed. Statistical analyses were performed using the Wilcoxon signed-rank test and Spearman correlation analysis (α = 0.05). <b>Results:</b> Twelve patients were included. No statistically significant difference was found between the two methods in VAS scores assessing patient-reported comfort and experience. Recording time was significantly shorter for the recording of conventionally determined CR (<i>p</i> = 0.002). No statistically significant correlation was found between recording time and patient-reported experience for both techniques (<i>p</i> > 0.05). <b>Conclusions:</b> Despite the need for clinician experience and patient compliance, PROMs for digitally determined CR were comparable to those of conventionally determined CR.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-03-15
DOI
https://doi.org/10.3390/jcm15062232
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital Recordings of Centric Relation Using Conventional and Digital Techniques: Patient-Reported Outcome Measures (PROMs)

kıvanç akça, Ece Selen Koçar
Journal of Clinical Medicine
Orthodontics and Dentofacial Orthopedics
article

Digital Recordings of Centric Relation Using Conventional and Digital Techniques: Patient-Reported Outcome Measures (PROMs)

kıvanç akça, Ece Selen Koçar
article en

Abstract

<b>Background/Objectives:</b> Centric relation (CR) is a reproducible mandibular reference position that plays a critical role in complex prosthodontic cases. With the advent of digital jaw-tracking devices, CR can now be recorded with greater precision through fully digital methods. This study aimed to compare patient-reported outcome measures (PROMs) for the recording of CR determined with conventional and digital techniques. <b>Methods:</b> Patients requiring occlusal rehabilitation due to bilateral loss of posterior support in the maxilla were included. Two different jaw relation recording techniques were applied: conventionally determined CR and digitally determined CR. The former was determined using bimanual manipulation, while the latter through multiple mandibular closure recordings performed with an anterior plateau using a jaw-tracking device. PROMs were assessed using Visual Analog Scale (VAS) to evaluate patient experience during jaw relation recording and comfort during restoration try-in. The recording time for both techniques was documented, and the correlation between recording time and VAS scores related to the recording procedure was analyzed. Statistical analyses were performed using the Wilcoxon signed-rank test and Spearman correlation analysis (α = 0.05). <b>Results:</b> Twelve patients were included. No statistically significant difference was found between the two methods in VAS scores assessing patient-reported comfort and experience. Recording time was significantly shorter for the recording of conventionally determined CR (<i>p</i> = 0.002). No statistically significant correlation was found between recording time and patient-reported experience for both techniques (<i>p</i> > 0.05). <b>Conclusions:</b> Despite the need for clinician experience and patient compliance, PROMs for digitally determined CR were comparable to those of conventionally determined CR.

Journal of Clinical MedicineVol. 15(6)
Hacettepe University (TR)
Openalex Percentile: Top 21%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.