Experimental Study on the Operational Performance of a Household Split-Type Air Conditioner Based on Evaporative Cooling Technology

With the escalating energy consumption of air conditioning systems worldwide, reducing such energy use has become a critical research priority. Evaporative cooling technology plays a significant role in reducing the energy consumption of existing air conditioning systems, especially by enhancing the heat exchange efficiency of condensers. This paper presents the design of an evaporative cooling household split-type air conditioner (SAC) that employs a submerged water method. By utilizing motor-driven rotation, the water distributor ensures full and even water distribution across a double-layer wet pad. Additionally, condensate water is recycled, and direct evaporative cooling (DEC) technology is applied to lower the condenser temperature, thereby achieving energy savings. Experiments were conducted under various meteorological conditions, comparing the performance of the split air conditioning system with the water distributor to that of the system without it. The comparative experiments revealed that the average air temperature differences at the inlet and outlet of the water distributor were 8.7 °C and 4.8 °C, respectively, with maximum air temperature differences reaching 12.3 °C and 8.2 °C, respectively. Compared to the system without the water distributor, the average condensing temperature at the condenser outlet of the system with the water distributor was reduced by 2.6 °C and 2.1 °C. Moreover, within an 11 h operation period, the average system coefficient of performance (COP) increased by 22.6% and 18.2%, respectively, and the energy savings reached 17.9% and 12.7%, respectively.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-03-16
DOI
https://doi.org/10.3390/buildings16061169
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on the Operational Performance of a Household Split-Type Air Conditioner Based on Evaporative Cooling Technology

Zihui Li, Junjie Jin, Shichao Wang, Xubo Zhao et al.
Buildings
Adsorption and Cooling Systems
article

Experimental Study on the Operational Performance of a Household Split-Type Air Conditioner Based on Evaporative Cooling Technology

Zihui Li, Junjie Jin, Shichao Wang, Xubo Zhao, Tingting Yu, Jingru Zhang, Xue Han
article en

Abstract

With the escalating energy consumption of air conditioning systems worldwide, reducing such energy use has become a critical research priority. Evaporative cooling technology plays a significant role in reducing the energy consumption of existing air conditioning systems, especially by enhancing the heat exchange efficiency of condensers. This paper presents the design of an evaporative cooling household split-type air conditioner (SAC) that employs a submerged water method. By utilizing motor-driven rotation, the water distributor ensures full and even water distribution across a double-layer wet pad. Additionally, condensate water is recycled, and direct evaporative cooling (DEC) technology is applied to lower the condenser temperature, thereby achieving energy savings. Experiments were conducted under various meteorological conditions, comparing the performance of the split air conditioning system with the water distributor to that of the system without it. The comparative experiments revealed that the average air temperature differences at the inlet and outlet of the water distributor were 8.7 °C and 4.8 °C, respectively, with maximum air temperature differences reaching 12.3 °C and 8.2 °C, respectively. Compared to the system without the water distributor, the average condensing temperature at the condenser outlet of the system with the water distributor was reduced by 2.6 °C and 2.1 °C. Moreover, within an 11 h operation period, the average system coefficient of performance (COP) increased by 22.6% and 18.2%, respectively, and the energy savings reached 17.9% and 12.7%, respectively.

BuildingsVol. 16(6)
Henan University of Urban Construction (CN)
Affordable and clean energy
Openalex Percentile: Top 21%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Study on the Operational Performance of a Household Split-Type Air Conditioner Based on Evaporative Cooling Technology — Zihui Li, Junjie Jin, et al. · Buildings (2026) | TGRS Research Map | TGRS