RTSense: A Fabric-based Wearable System for Return-To-Sport Assessment of Anterior Cruciate Ligament Injuries

Return-to-sport (RTS) assessment is critical for patients recovering from anterior cruciate ligament (ACL) injuries, who face a high risk of re-injury. A key requirement is accurate monitoring of knee flexion during high-dynamic tasks where knee motion is coupled across three anatomical planes. Motion capture offers gold-standard accuracy but requires specialized infrastructure and controlled environments; inertial measurement units are portable but often degrade due to sensor displacement under intense motion. Fabric sensors are comfortable and stable, yet existing single-plane designs cannot reliably separate the main flexion from coupled multi-plane motion. We present RTSense, the first fabric-based system capable of accurately estimating knee flexion during high-dynamic RTS tasks. RTSense places multiple fabric sensors in a cross-plane layout to capture complementary biomechanical cues, addressing two key challenges: fabric data distribution shifts and the bio-structural coupling of multi-plane knee motion. Building on this layout, RTSense combines a fabric-specific data augmentation framework to handle inter-subject and intra-subject variability with a disentangling model that leverages cross-plane features to recover knee flexion angles. To validate RTSense, we collaborate with a medical center and collect data from 35 participants, including ACL patients and healthy controls across athlete and non-athlete groups. RTSense achieves an average RMSE of 3.96° for knee flexion, 3.71° for peak flexion, and yields 100% correct RTS decisions, demonstrating its potential to support reliable RTS decision-making.

Authors

Institutions

Publication Details

Journal
Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies
Published
2026-03-16
DOI
https://doi.org/10.1145/3789686
Citations
1
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
39.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RTSense: A Fabric-based Wearable System for Return-To-Sport Assessment of Anterior Cruciate Ligament Injuries

Xinyi Zhang, Baichen Yang, Qinghui Shao, Jiaxi Zhang et al.
1 citations
Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies
Knee injuries and reconstruction techniques
39.15
article

RTSense: A Fabric-based Wearable System for Return-To-Sport Assessment of Anterior Cruciate Ligament Injuries

Xinyi Zhang, Baichen Yang, Qinghui Shao, Jiaxi Zhang, Qian Zhang, Xin He, Michael Ong Tim-yun, Zuru Liang, Patrick Yung Shu-hang
article en
1 citations

Abstract

Return-to-sport (RTS) assessment is critical for patients recovering from anterior cruciate ligament (ACL) injuries, who face a high risk of re-injury. A key requirement is accurate monitoring of knee flexion during high-dynamic tasks where knee motion is coupled across three anatomical planes. Motion capture offers gold-standard accuracy but requires specialized infrastructure and controlled environments; inertial measurement units are portable but often degrade due to sensor displacement under intense motion. Fabric sensors are comfortable and stable, yet existing single-plane designs cannot reliably separate the main flexion from coupled multi-plane motion. We present RTSense, the first fabric-based system capable of accurately estimating knee flexion during high-dynamic RTS tasks. RTSense places multiple fabric sensors in a cross-plane layout to capture complementary biomechanical cues, addressing two key challenges: fabric data distribution shifts and the bio-structural coupling of multi-plane knee motion. Building on this layout, RTSense combines a fabric-specific data augmentation framework to handle inter-subject and intra-subject variability with a disentangling model that leverages cross-plane features to recover knee flexion angles. To validate RTSense, we collaborate with a medical center and collect data from 35 participants, including ACL patients and healthy controls across athlete and non-athlete groups. RTSense achieves an average RMSE of 3.96° for knee flexion, 3.71° for peak flexion, and yields 100% correct RTS decisions, demonstrating its potential to support reliable RTS decision-making.

Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous TechnologiesVol. 10(1)
Chinese University of Hong Kong (HK), Hong Kong University of Science and Technology (HK), Hong Kong College of Technology (CN), University of Hong Kong (HK)
Industry, innovation and infrastructure
Openalex Percentile: Top 0%
Knee injuries and reconstruction techniques
39.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.