3D-StyleGAN2-ADA: Volumetric Synthesis of Realistic Prostate T2W MRI

This work investigates the extension of StyleGAN2-ADA to three-dimensional prostate T2-weighted (T2W) MRI generation. The architecture is adapted to operate on 3D anisotropic volumes, enabling stable training at a clinically relevant resolution of 256×256×24, where a baseline 3D-StyleGAN fails to converge. Quantitative evaluation using Fréchet Inception Distance (FID), Kernel Inception Distance (KID), and generative Precision-Recall metrics demonstrates substantial improvements over a 3D-StyleGAN baseline. Specifically, FID decreased from 114.2 to 27.3, while generative Precision increased from 0.22 to 0.82, indicating markedly improved fidelity and alignment with the real data distribution. Beyond generative metrics, the synthetic volumes were evaluated through radiomic feature analysis and downstream prostate segmentation. Synthetic data augmentation resulted in segmentation performance comparable to real-data training, supporting that volumetric generation preserves anatomically relevant structures, while multivariate radiomic analyses showed strong global feature alignment between real and synthetic volumes. These findings indicate that a 3D extension of StyleGAN2-ADA enables stable high-resolution volumetric prostate MRI synthesis while preserving anatomically coherent structure and global radiomic characteristics.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2026-03-14
DOI
https://doi.org/10.3390/jimaging12030130
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-StyleGAN2-ADA: Volumetric Synthesis of Realistic Prostate T2W MRI

Claudia L. Giardina, Veronica Vilaplana
Journal of Imaging
Prostate Cancer Diagnosis and Treatment
article

3D-StyleGAN2-ADA: Volumetric Synthesis of Realistic Prostate T2W MRI

Claudia L. Giardina, Veronica Vilaplana
article en

Abstract

This work investigates the extension of StyleGAN2-ADA to three-dimensional prostate T2-weighted (T2W) MRI generation. The architecture is adapted to operate on 3D anisotropic volumes, enabling stable training at a clinically relevant resolution of 256×256×24, where a baseline 3D-StyleGAN fails to converge. Quantitative evaluation using Fréchet Inception Distance (FID), Kernel Inception Distance (KID), and generative Precision-Recall metrics demonstrates substantial improvements over a 3D-StyleGAN baseline. Specifically, FID decreased from 114.2 to 27.3, while generative Precision increased from 0.22 to 0.82, indicating markedly improved fidelity and alignment with the real data distribution. Beyond generative metrics, the synthetic volumes were evaluated through radiomic feature analysis and downstream prostate segmentation. Synthetic data augmentation resulted in segmentation performance comparable to real-data training, supporting that volumetric generation preserves anatomically relevant structures, while multivariate radiomic analyses showed strong global feature alignment between real and synthetic volumes. These findings indicate that a 3D extension of StyleGAN2-ADA enables stable high-resolution volumetric prostate MRI synthesis while preserving anatomically coherent structure and global radiomic characteristics.

Journal of ImagingVol. 12(3)
Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 21%
Prostate Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.