Cone-beam computed tomography (CBCT) enables three-dimensional evaluation of maxillary transverse relationships; however, no consensus exists regarding which CBCT-based diagnostic approach should be used, and the reliability and diagnostic consistency of available systems remain unclear. In this study, the reproducibility and diagnostic agreement of four established CBCT-based transverse assessment methods were compared. Ninety-eight patients (mean age: 21.57 years) underwent CBCT. Four diagnostic systems—Penn transverse analysis (PTA), Miner CBCT transverse analysis (CBTA), Yonsei transverse analysis (YTA), and Case Western Reserve University transverse analysis (CWRUTA)—were applied. Two calibrated examiners performed all the measurements twice with a two-week interval. Reliability was assessed using intraclass correlation coefficients (ICCs), Dahlberg’s error, and Bland–Altman analyses. Diagnostic agreement was evaluated using Cohen’s kappa and cross-method comparisons across skeletal subtypes. All four methods demonstrated acceptable reproducibility (ICC > 0.75), but variation existed across measurements. Compared with inclination-dependent parameters, skeletal width measurements were more repeatable. YTA demonstrated the highest overall reliability and the smallest systematic and random errors, whereas the inclination variables in CWRUTA exhibited the greatest variability and systematic bias. Diagnostic agreement varied across systems and was not interchangeable. YTA and CBTA showed the strongest agreement, whereas CWRUTA classified the greatest proportion of patients as deficient. Agreement increased in skeletal Class III and was lowest in Class II. CBCT-based transverse diagnostic systems differ in both measurement reproducibility and diagnostic output. YTA demonstrated the most consistent performance and may serve as a reliable primary assessment tool, whereas inclination-based analyses should be interpreted cautiously and in a clinical context. Because no single method fully captures skeletal and dentoalveolar dimensions, a combined diagnostic approach may be more appropriate until standardized criteria and automated CBCT analysis tools become available.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-03-16
DOI
https://doi.org/10.1186/s12903-026-08107-x
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative reliability and agreement of CBCT-based measurement approaches for assessing maxillary transverse deficiency

Z Wang, Hanyu Lin, Yuchun Zou, Zhonghan Chen et al.
BMC Oral Health
Orthodontics and Dentofacial Orthopedics
article

Comparative reliability and agreement of CBCT-based measurement approaches for assessing maxillary transverse deficiency

Z Wang, Hanyu Lin, Yuchun Zou, Zhonghan Chen, Qian Yu, L P Xu, Jingwen Cai, Linxin Chen, Sihang Chen
article en

Abstract

Cone-beam computed tomography (CBCT) enables three-dimensional evaluation of maxillary transverse relationships; however, no consensus exists regarding which CBCT-based diagnostic approach should be used, and the reliability and diagnostic consistency of available systems remain unclear. In this study, the reproducibility and diagnostic agreement of four established CBCT-based transverse assessment methods were compared. Ninety-eight patients (mean age: 21.57 years) underwent CBCT. Four diagnostic systems—Penn transverse analysis (PTA), Miner CBCT transverse analysis (CBTA), Yonsei transverse analysis (YTA), and Case Western Reserve University transverse analysis (CWRUTA)—were applied. Two calibrated examiners performed all the measurements twice with a two-week interval. Reliability was assessed using intraclass correlation coefficients (ICCs), Dahlberg’s error, and Bland–Altman analyses. Diagnostic agreement was evaluated using Cohen’s kappa and cross-method comparisons across skeletal subtypes. All four methods demonstrated acceptable reproducibility (ICC > 0.75), but variation existed across measurements. Compared with inclination-dependent parameters, skeletal width measurements were more repeatable. YTA demonstrated the highest overall reliability and the smallest systematic and random errors, whereas the inclination variables in CWRUTA exhibited the greatest variability and systematic bias. Diagnostic agreement varied across systems and was not interchangeable. YTA and CBTA showed the strongest agreement, whereas CWRUTA classified the greatest proportion of patients as deficient. Agreement increased in skeletal Class III and was lowest in Class II. CBCT-based transverse diagnostic systems differ in both measurement reproducibility and diagnostic output. YTA demonstrated the most consistent performance and may serve as a reliable primary assessment tool, whereas inclination-based analyses should be interpreted cautiously and in a clinical context. Because no single method fully captures skeletal and dentoalveolar dimensions, a combined diagnostic approach may be more appropriate until standardized criteria and automated CBCT analysis tools become available.

BMC Oral Health
Fujian Medical University (CN)
Openalex Percentile: Top 21%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.