Shielding design for IECF devices: ensuring safety through material analysis
Inertial Electrostatic Confinement Fusion (IECF) devices have garnered increased recognition for their potential as compact, portable neutron sources for use in the generation of medical isotopes and various neutron-based interrogation techniques. This study investigates the shielding requirements for a laboratory enclosure that houses a deuterium-deuterium (DD) fueled IECF device. The simulation framework was first validated by reproducing the ambient dose equivalent, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m1"> <mml:mrow> <mml:msup> <mml:mrow> <mml:mi>H</mml:mi> </mml:mrow> <mml:mrow> <mml:mo>*</mml:mo> </mml:mrow> </mml:msup> <mml:mrow> <mml:mo stretchy="false">(</mml:mo> <mml:mrow> <mml:mn>10</mml:mn> </mml:mrow> <mml:mo stretchy="false">)</mml:mo> </mml:mrow> </mml:mrow> </mml:math> , conversion coefficient reference values, confirming the suitability of Geant4 for dose deposition measurements. Simulations were then used to evaluate neutron moderation and removal in various shielding materials, investigating five different concrete constituents and water, with the performance assessed relative to UK Ionising Radiations Regulations 2017 (IRR17) dose-rate limits. Neutron and gamma fluences were tallied in defined volumes of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m2"> <mml:mrow> <mml:mn>40</mml:mn> <mml:mspace width="0.3333em"/> <mml:mi>c</mml:mi> <mml:msup> <mml:mrow> <mml:mi>m</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>3</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> , <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m3"> <mml:mrow> <mml:msup> <mml:mrow> <mml:mi>H</mml:mi> </mml:mrow> <mml:mrow> <mml:mo>*</mml:mo> </mml:mrow> </mml:msup> <mml:mrow> <mml:mo stretchy="false">(</mml:mo> <mml:mrow> <mml:mn>10</mml:mn> </mml:mrow> <mml:mo stretchy="false">)</mml:mo> </mml:mrow> </mml:mrow> </mml:math> measurements were then calculated using ICRP 74 conversion coefficients. The simulation results show that an IECF device can be operated safely at a neutron rate of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m4"> <mml:mrow> <mml:mn>1</mml:mn> <mml:mo>×</mml:mo> <mml:mn>1</mml:mn> <mml:msup> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> <mml:mrow> <mml:mn>5</mml:mn> </mml:mrow> </mml:msup> <mml:mspace width="0.3333em"/> <mml:mi>n</mml:mi> <mml:msup> <mml:mrow> <mml:mi>s</mml:mi> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> within public dose limits, recording <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m5"> <mml:mrow> <mml:mo><</mml:mo> <mml:mn>500</mml:mn> <mml:mspace width="0.3333em"/> <mml:mi>n</mml:mi> <mml:mi>S</mml:mi> <mml:mi>v</mml:mi> <mml:mspace width="0.3333em"/> <mml:msup> <mml:mrow> <mml:mi>h</mml:mi> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> at a distance of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m6"> <mml:mrow> <mml:mn>1.6</mml:mn> <mml:mspace width="0.3333em"/> <mml:mi>m</mml:mi> </mml:mrow> </mml:math> , with <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m7"> <mml:mrow> <mml:mn>10</mml:mn> <mml:mspace width="0.3333em"/> <mml:mi>c</mml:mi> <mml:mi>m</mml:mi> </mml:mrow> </mml:math> of all concretes tested other than Barite (Heavy) concrete, which measured <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m8"> <mml:mrow> <mml:mn>501</mml:mn> <mml:mspace width="0.3333em"/> <mml:mi>n</mml:mi> <mml:mi>S</mml:mi> <mml:mi>v</mml:mi> <mml:mspace width="0.3333em"/> <mml:msup> <mml:mrow> <mml:mi>h</mml:mi> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> . The results also show that a safe environment for radiation workers can be constructed, allowing the device to be operated at <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m9"> <mml:mrow> <mml:mn>1</mml:mn> <mml:mo>×</mml:mo> <mml:mn>1</mml:mn> <mml:msup> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> <mml:mrow> <mml:mn>7</mml:mn> </mml:mrow> </mml:msup> <mml:mspace width="0.3333em"/> <mml:mi>n</mml:mi> <mml:msup> <mml:mrow> <mml:mi>s</mml:mi> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> if <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m10"> <mml:mrow> <mml:mn>30</mml:mn> <mml:mspace width="0.3333em"/> <mml:mi>c</mml:mi> <mml:mi>m</mml:mi> </mml:mrow> </mml:math>
Authors
- Mahmoud Bakr (ORCID: https://orcid.org/0000-0001-5761-2903)
- Edward Martin
- Thomas B. Scott
Institutions
- Astrobiology Center (JP)
- Bristol Robotics Laboratory (GB)
- Assiut University (EG)
Publication Details
- Journal
- Frontiers in Nuclear Engineering
- Published
- 2026-03-16
- DOI
- https://doi.org/10.3389/fnuen.2026.1757155
- Primary Topic
- Fusion and Plasma Physics Studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- University of Bristol