Thermoluminescence Study of Natural CaCO₃ Mineral from Konya, Türkiye: Effect of Annealing on Signal Quality

In this study, thermoluminescence analyses were performed on natural CaCO₃ mineral sample obtained from Konya region after exposure to beta irradiation. Examining the thermoluminescence curve of the un-annealed sample, it was determined that there is a maximum at 100 °C and a tail extension around 250 °C. To detect the presence of deep traps, annealing was performed at temperatures between 400-800°C. It was decided that the optimum annealing temperature was 700°C, with a duration of 60 minutes. The characteristics of dose sensitivity, linearity, and reusability were analyzed to identify the effective thermoluminescence (TL) maximum on the high-temperature side of the spectrum. The whole TL glow curve was investigated through the Tm-Tstop experiment. Tm-Tstop experiment analysis determined that the luminescence curve of the natural CaCO3 mineral sample is complex.

Authors

Institutions

Publication Details

Journal
Black Sea Journal of Engineering and Science
Published
2026-03-15
DOI
https://doi.org/10.34248/bsengineering.1867100
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermoluminescence Study of Natural CaCO₃ Mineral from Konya, Türkiye: Effect of Annealing on Signal Quality

Hamide İmal Avcı
Black Sea Journal of Engineering and Science
Luminescence Properties of Advanced Materials
article

Thermoluminescence Study of Natural CaCO₃ Mineral from Konya, Türkiye: Effect of Annealing on Signal Quality

Hamide İmal Avcı
article en

Abstract

In this study, thermoluminescence analyses were performed on natural CaCO₃ mineral sample obtained from Konya region after exposure to beta irradiation. Examining the thermoluminescence curve of the un-annealed sample, it was determined that there is a maximum at 100 °C and a tail extension around 250 °C. To detect the presence of deep traps, annealing was performed at temperatures between 400-800°C. It was decided that the optimum annealing temperature was 700°C, with a duration of 60 minutes. The characteristics of dose sensitivity, linearity, and reusability were analyzed to identify the effective thermoluminescence (TL) maximum on the high-temperature side of the spectrum. The whole TL glow curve was investigated through the Tm-Tstop experiment. Tm-Tstop experiment analysis determined that the luminescence curve of the natural CaCO3 mineral sample is complex.

Black Sea Journal of Engineering and ScienceVol. 9(2)
Selçuk University (TR)
Konya Teknik Üniversitesi
Openalex Percentile: Top 22%
Luminescence Properties of Advanced Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.