Estimating the arterial CO2 partial pressure by sensor fusion of end-tidal and transcutaneous CO2 measurements

Closed-loop control of the arterial CO2 partial pressure (PaCO2) could improve respiratory care in preterm neonates but requires an accurate, continuous, and noninvasive surrogate of PaCO2. We propose fusing end-tidal and transcutaneous CO2 measurements to obtain such a signal. We evaluate two fusion approaches: (i) a linear combination of the two measurements and (ii) a state-augmented Kalman filter. Both methods are tested on mechanical ventilation data from five preterm lambs. In this dataset, both fusion approaches improve PaCO2 estimation compared with either end-tidal or transcutaneous CO2 alone, supporting their potential for future closed-loop ventilation systems.

Authors

Institutions

Publication Details

Journal
Infinite Science GmbH
Published
2025-12-17
DOI
https://doi.org/10.18416/automed.2026.2534
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimating the arterial CO2 partial pressure by sensor fusion of end-tidal and transcutaneous CO2 measurements

Valerie Pfannschmidt, Mark Schoberer, André Stollenwerk, Sara Hillmann
Infinite Science GmbH
Neonatal Respiratory Health Research
article

Estimating the arterial CO2 partial pressure by sensor fusion of end-tidal and transcutaneous CO2 measurements

Valerie Pfannschmidt, Mark Schoberer, André Stollenwerk, Sara Hillmann
article en

Abstract

Closed-loop control of the arterial CO2 partial pressure (PaCO2) could improve respiratory care in preterm neonates but requires an accurate, continuous, and noninvasive surrogate of PaCO2. We propose fusing end-tidal and transcutaneous CO2 measurements to obtain such a signal. We evaluate two fusion approaches: (i) a linear combination of the two measurements and (ii) a state-augmented Kalman filter. Both methods are tested on mechanical ventilation data from five preterm lambs. In this dataset, both fusion approaches improve PaCO2 estimation compared with either end-tidal or transcutaneous CO2 alone, supporting their potential for future closed-loop ventilation systems.

Infinite Science GmbH
Universitätsklinikum Aachen (DE), Embedded Systems (United States) (US), RWTH Aachen University (DE)
Openalex Percentile: Top 23%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.