Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis

This study aimed to evaluate the mechanical performance of CF/PEEK composite plates for external fixation through finite element analysis (FEA), and to explore the impact of different screw placement patterns on fixation stability. A proximal tibial fracture model treated with external fixation was constructed using FEA. Longitudinal loading was applied to simulate walking stress, with additional internal and external rotational torques to mimic load-bearing movement. Mechanical responses of titanium alloy and CF/PEEK plates were compared under three loading conditions: longitudinal, longitudinal with internal rotation, and longitudinal with external rotation. Screw alignment was also varied between linear and non-linear configurations to assess its biomechanical influence. Compared to titanium alloy group, the linear CF/PEEK plate exhibited a mild increase in displacement of 0.232-0.386 mm (8.23-11.14%), accompanied by a substantial reduction in plate stress of 46.03-80.84%. At the fracture site, interfragmentary displacement increased slightly by 0.105-0.132 mm (5.56-6.74%), while fracture-site stress increased by 3.119-18.029 MPa (18.30-63.20%). The non-linear CF/PEEK plate demonstrated a similar biomechanical performance, with no significant differences compared with the linear configuration. For external plate fixation, CF/PEEK represents a promising alternative to conventional titanium alloy plates. By allowing an acceptable level of local micromotion, CF/PEEK plates significantly reduce stress in the plate and screws while increasing stress transfer at the fracture site. This load-sharing behavior may mitigate stress shielding associated with traditional metallic plates and thereby promote early biological fracture healing.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-14
DOI
https://doi.org/10.1038/s41598-026-43182-8
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis

Qing Yan, Si Wang, Jianming Chen, Ning Ni et al.
Scientific Reports
Bone fractures and treatments
article

Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis

Qing Yan, Si Wang, Jianming Chen, Ning Ni, Jingwei Zhang, Lin An, Zuodong Zhao
article en

Abstract

This study aimed to evaluate the mechanical performance of CF/PEEK composite plates for external fixation through finite element analysis (FEA), and to explore the impact of different screw placement patterns on fixation stability. A proximal tibial fracture model treated with external fixation was constructed using FEA. Longitudinal loading was applied to simulate walking stress, with additional internal and external rotational torques to mimic load-bearing movement. Mechanical responses of titanium alloy and CF/PEEK plates were compared under three loading conditions: longitudinal, longitudinal with internal rotation, and longitudinal with external rotation. Screw alignment was also varied between linear and non-linear configurations to assess its biomechanical influence. Compared to titanium alloy group, the linear CF/PEEK plate exhibited a mild increase in displacement of 0.232-0.386 mm (8.23-11.14%), accompanied by a substantial reduction in plate stress of 46.03-80.84%. At the fracture site, interfragmentary displacement increased slightly by 0.105-0.132 mm (5.56-6.74%), while fracture-site stress increased by 3.119-18.029 MPa (18.30-63.20%). The non-linear CF/PEEK plate demonstrated a similar biomechanical performance, with no significant differences compared with the linear configuration. For external plate fixation, CF/PEEK represents a promising alternative to conventional titanium alloy plates. By allowing an acceptable level of local micromotion, CF/PEEK plates significantly reduce stress in the plate and screws while increasing stress transfer at the fracture site. This load-sharing behavior may mitigate stress shielding associated with traditional metallic plates and thereby promote early biological fracture healing.

Scientific Reports
Ningbo University (CN), University of Nottingham Ningbo China (CN), Ningbo University of Technology (CN), Ningbo No. 2 Hospital (CN), Ningbo No.6 Hospital (CN), KU Leuven (BE)
Openalex Percentile: Top 23%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.