Real-Time Haptic Testbed for Path-Following Control in Rehabilitation: System and Performance Characterization

Developing path-following haptic guidance for body weight support (BWS) rehabilitation systems requires validated, risk-free real-time infrastructure before implementing advanced control strategies. This paper presents the architecture and preliminary validation of a scaled haptic testbed integrating a Beckhoff CX2043 real-time computer with a Novint Falcon haptic device. The system employs a distributed architecture: MATLAB/Simulink controllers compiled to TwinCAT PLC code executed on the embedded real-time platform, communicating via UDP with a multi-threaded C++ application interfacing the haptic device. We characterize the system's timing performance, achieving 1?kHz control loop execution on the real-time controller with current end-to-end latencies of approximately 20?ms. Preliminary tests with sit-to-stand trajectories derived from motion capture data confirm functional path-following capability. This work establishes the foundational infrastructure for subsequent development and comparison of assist-as-needed control strategies on a safe test bed that can be translated to “the FLOAT” BWS system (Reha-Stim Medtec AG, Schlieren, Switzerland).

Authors

Institutions

Publication Details

Journal
Infinite Science GmbH
Published
2025-12-17
DOI
https://doi.org/10.18416/automed.2026.2521
Primary Topic
Teleoperation and Haptic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Haptic Testbed for Path-Following Control in Rehabilitation: System and Performance Characterization

Georg Rauter, Nicolas Gerig, Lauren Chee, Sébastien Muheim et al.
Infinite Science GmbH
Teleoperation and Haptic Systems
article

Real-Time Haptic Testbed for Path-Following Control in Rehabilitation: System and Performance Characterization

Georg Rauter, Nicolas Gerig, Lauren Chee, Sébastien Muheim, Sri Sai Sathvik Kadimisetty
article en

Abstract

Developing path-following haptic guidance for body weight support (BWS) rehabilitation systems requires validated, risk-free real-time infrastructure before implementing advanced control strategies. This paper presents the architecture and preliminary validation of a scaled haptic testbed integrating a Beckhoff CX2043 real-time computer with a Novint Falcon haptic device. The system employs a distributed architecture: MATLAB/Simulink controllers compiled to TwinCAT PLC code executed on the embedded real-time platform, communicating via UDP with a multi-threaded C++ application interfacing the haptic device. We characterize the system's timing performance, achieving 1?kHz control loop execution on the real-time controller with current end-to-end latencies of approximately 20?ms. Preliminary tests with sit-to-stand trajectories derived from motion capture data confirm functional path-following capability. This work establishes the foundational infrastructure for subsequent development and comparison of assist-as-needed control strategies on a safe test bed that can be translated to “the FLOAT” BWS system (Reha-Stim Medtec AG, Schlieren, Switzerland).

Infinite Science GmbH
University of Basel (CH)
Industry, innovation and infrastructure
Openalex Percentile: Top 38%
Teleoperation and Haptic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.