Spherical Nucleic Acid Stabilized Cage Type Three‐Dimensional Electrochemiluminescence Probe for Sensitive and Amplification‐Free Diagnosis of Infectious Diseases

ABSTRACT Accurate nucleic acid‐based pathogen diagnosis is critical for clinical treatment and epidemic control. However, present gold‐standard testing methods based on nucleic acid amplification are limited by their time and labor‐intensive nature. Hence, we reported an amplification‐free assay that facilitates rapid, sensitive, and point‐of‐care detection of infectious diseases. Herein, spherical nucleic acid (SNA)‐stabilized cage‐type three‐dimensional electrochemiluminescence (ECL) reporter probe, constructed utilizing Ru(dcbpy) 3 Cl 2 ‐doped NH 2 ‐MIL‐101 (Fe) metal‐organic framework, was combined with a paper‐based bipolar electrode ECL sensor. Furthermore, surface modifications were performed using polydopamine and SNAs to further improve the stability. Notably, compared with the ordinary Ru(dcbpy) 3 Cl 2 , the modified ECL probe attained 10 3 ‐fold enhancement in luminous efficiency. The developed ECL‐based nucleic acid biosensing system offers the advantages of simplicity, portability, low cost, and user‐friendly nucleic acid detection, with a sample‐to‐answer time of approximately 15 min. Additionally, the effectiveness of the developed assay in detecting pathogenic nucleic acid was assessed using Mpox and SARS‐Cov‐2, exhibiting a wide dynamic range from 33 to 10 10 aM and limits of detection as low as 3 copies/µL. Furthermore, the assay exhibited 100% sensitivity and specificity when validated against quantitative polymerase chain reaction‐based detection using clinical samples. Altogether, the findings of this study show the efficacy of the novel developed SNA‐stabilized cage‐type 3D ECL probe‐enhanced nucleic acid assay, along with its potential as a promising paradigm for point‐of‐care diagnosis of infectious pathogens.

Authors

Institutions

Publication Details

Journal
Exploration
Published
2026-03-14
DOI
https://doi.org/10.1002/exp.20240451
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spherical Nucleic Acid Stabilized Cage Type Three‐Dimensional Electrochemiluminescence Probe for Sensitive and Amplification‐Free Diagnosis of Infectious Diseases

Yideng Jiang, Yuhui Liao, Lunjing Liu, J. Wang et al.
Exploration
Advanced biosensing and bioanalysis techniques
article

Spherical Nucleic Acid Stabilized Cage Type Three‐Dimensional Electrochemiluminescence Probe for Sensitive and Amplification‐Free Diagnosis of Infectious Diseases

Yideng Jiang, Yuhui Liao, Lunjing Liu, J. Wang, Wei J. Wang, Yang Yang, Wenjie Wu, Jinyan Lin, Yu Fu, Wenlu Song, Bowen Shu, Huiyi Yang
article en

Abstract

ABSTRACT Accurate nucleic acid‐based pathogen diagnosis is critical for clinical treatment and epidemic control. However, present gold‐standard testing methods based on nucleic acid amplification are limited by their time and labor‐intensive nature. Hence, we reported an amplification‐free assay that facilitates rapid, sensitive, and point‐of‐care detection of infectious diseases. Herein, spherical nucleic acid (SNA)‐stabilized cage‐type three‐dimensional electrochemiluminescence (ECL) reporter probe, constructed utilizing Ru(dcbpy) 3 Cl 2 ‐doped NH 2 ‐MIL‐101 (Fe) metal‐organic framework, was combined with a paper‐based bipolar electrode ECL sensor. Furthermore, surface modifications were performed using polydopamine and SNAs to further improve the stability. Notably, compared with the ordinary Ru(dcbpy) 3 Cl 2 , the modified ECL probe attained 10 3 ‐fold enhancement in luminous efficiency. The developed ECL‐based nucleic acid biosensing system offers the advantages of simplicity, portability, low cost, and user‐friendly nucleic acid detection, with a sample‐to‐answer time of approximately 15 min. Additionally, the effectiveness of the developed assay in detecting pathogenic nucleic acid was assessed using Mpox and SARS‐Cov‐2, exhibiting a wide dynamic range from 33 to 10 10 aM and limits of detection as low as 3 copies/µL. Furthermore, the assay exhibited 100% sensitivity and specificity when validated against quantitative polymerase chain reaction‐based detection using clinical samples. Altogether, the findings of this study show the efficacy of the novel developed SNA‐stabilized cage‐type 3D ECL probe‐enhanced nucleic acid assay, along with its potential as a promising paradigm for point‐of‐care diagnosis of infectious pathogens.

Exploration
Kunming Medical University (CN), Ningxia Medical University (CN), Shenzhen Third People’s Hospital (CN)
Good health and well-being
Openalex Percentile: Top 22%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.