Detecting excessive and insufficient breathing effort with respiratory surface EMG

During mechanical ventilation risks for excessive and insufficient breathing effort directly determine patient outcomes through distinct injury mechanisms. Respiratory surface electromyography (sEMG) holds potential for monitoring breathing effort, however measurement of electrical activity in comparison to conventional pressure measurement exhibits systematic differences in timing and amplitude of inspiratory activity. In this article influences of neuromechanical delay (NMD) and coupling (NMC) on detection performance using sEMG compared to pressure measurements are investigated. Results indicate excellent performance if sEMG measurements are corrected for both NMD and NMC. However, using generalized values for NMD and NMC do not achieve improvements, highlighting the importance of individualized calibration.

Authors

Institutions

Publication Details

Journal
Infinite Science GmbH
Published
2025-12-05
DOI
https://doi.org/10.18416/automed.2026.2478
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detecting excessive and insufficient breathing effort with respiratory surface EMG

Jan Graßhoff, Philipp Rostalski, Niklas M. Carbon, Tjorben Lerg et al.
Infinite Science GmbH
Muscle activation and electromyography studies
article

Detecting excessive and insufficient breathing effort with respiratory surface EMG

Jan Graßhoff, Philipp Rostalski, Niklas M. Carbon, Tjorben Lerg, Steffen Weber-Carstens
article en

Abstract

During mechanical ventilation risks for excessive and insufficient breathing effort directly determine patient outcomes through distinct injury mechanisms. Respiratory surface electromyography (sEMG) holds potential for monitoring breathing effort, however measurement of electrical activity in comparison to conventional pressure measurement exhibits systematic differences in timing and amplitude of inspiratory activity. In this article influences of neuromechanical delay (NMD) and coupling (NMC) on detection performance using sEMG compared to pressure measurements are investigated. Results indicate excellent performance if sEMG measurements are corrected for both NMD and NMC. However, using generalized values for NMD and NMC do not achieve improvements, highlighting the importance of individualized calibration.

Infinite Science GmbH
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Universitätsklinikum Erlangen (DE), Fraunhofer-Einrichtung für Individualisierte Medizintechnik (DE), Charité - Universitätsmedizin Berlin (DE), University of Lübeck (DE)
Good health and well-being
Openalex Percentile: Top 37%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detecting excessive and insufficient breathing effort with respiratory surface EMG — Jan Graßhoff, Philipp Rostalski, et al. · Infinite Science GmbH (2025) | TGRS Research Map | TGRS