Effect of twisted blade roots on the performance and internal flow of non-volute centrifugal fan

In this paper, the effects of twisting blade roots on the performance and internal flow of the non-volute centrifugal fan are deeply studied by means of computational fluid dynamics and experiment tests. The midpoint of the blade root centerline as the twist center is defined and the twisting deformation is applied to both the leading and trailing edges. The pressure distribution inside the impeller is effectively improved by moderate blade root twist, the flow separation and secondary flow loss are also effectively reduced. The flow characteristics at the high angle of incident are mainly improved by the twist angle. At the design flow rate, the static pressure efficiency of the fans with twist angles of 5°, 15°, 25°, and 35°increased by 0.2%, 4.89%, 5.27%, and 4.38%, respectively compared with that of original centrifugal fan. It is obtained that at the low flow rate 0.9 Qn, the static pressure efficiency of the twist 5°, 15°, 25°, and 35° models are increased by 1.1%, 4.74%, 8.31%, and 8.88%, respectively compared with that of original centrifugal fan. However, at high flow rate, an excessive twist introduces a new separation zone and increases the length of the flow channel and aggravate the friction loss. The static pressure and static pressure efficiency of the twist 25°model arise as much as 2 Pa and 1.14% compared with that of the original non-volute centrifugal fan by experimental measurement and total pressure and total pressure efficiency of the twist 25°model arise as much as 12.4 Pa and 1.27%, respectively. These findings provide critical insights for optimizing centrifugal fan design through localized blade geometry modifications. In particular the part-load efficiency of centrifugal fan is effectively enhanced in engineering application.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy
Published
2026-03-14
DOI
https://doi.org/10.1177/09576509261435941
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of twisted blade roots on the performance and internal flow of non-volute centrifugal fan

Zhengdao Wang, W. Zhang, H. J. Yang, Wenbo Zhang et al.
Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy
Turbomachinery Performance and Optimization
article

Effect of twisted blade roots on the performance and internal flow of non-volute centrifugal fan

Zhengdao Wang, W. Zhang, H. J. Yang, Wenbo Zhang, Yikun Wei, Genqiang Shao, Zhikun Wang
article en

Abstract

In this paper, the effects of twisting blade roots on the performance and internal flow of the non-volute centrifugal fan are deeply studied by means of computational fluid dynamics and experiment tests. The midpoint of the blade root centerline as the twist center is defined and the twisting deformation is applied to both the leading and trailing edges. The pressure distribution inside the impeller is effectively improved by moderate blade root twist, the flow separation and secondary flow loss are also effectively reduced. The flow characteristics at the high angle of incident are mainly improved by the twist angle. At the design flow rate, the static pressure efficiency of the fans with twist angles of 5°, 15°, 25°, and 35°increased by 0.2%, 4.89%, 5.27%, and 4.38%, respectively compared with that of original centrifugal fan. It is obtained that at the low flow rate 0.9 Qn, the static pressure efficiency of the twist 5°, 15°, 25°, and 35° models are increased by 1.1%, 4.74%, 8.31%, and 8.88%, respectively compared with that of original centrifugal fan. However, at high flow rate, an excessive twist introduces a new separation zone and increases the length of the flow channel and aggravate the friction loss. The static pressure and static pressure efficiency of the twist 25°model arise as much as 2 Pa and 1.14% compared with that of the original non-volute centrifugal fan by experimental measurement and total pressure and total pressure efficiency of the twist 25°model arise as much as 12.4 Pa and 1.27%, respectively. These findings provide critical insights for optimizing centrifugal fan design through localized blade geometry modifications. In particular the part-load efficiency of centrifugal fan is effectively enhanced in engineering application.

Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy
Zhejiang Sci-Tech University (CN), Zhejiang Chint Electrics (China) (CN), Heat Transfer Research (United States) (US), Hefei General Machinery Research Institute (China) (CN), Endress+Hauser (Switzerland) (CH)
Affordable and clean energy
Openalex Percentile: Top 21%
Turbomachinery Performance and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.