Mechanical Analysis of Needles Used in Ultrasound-Guided Musculoskeletal Interventions.

We performed a mechanical analysis of the commonly used needles for ultrasound-guided interventions in the musculoskeletal system. Specifically, focusing on the ability to absorb potential physical loads and the degree of deformation during the procedure, the needle gauge best suited for those procedures is evaluated. A customized tensile-compression device was used for an experimental buckling strength test on three commonly used needle types with specific gauge sizes. The loss of structural integrity, loss of needle stability, and buckling load were modeled also theoretically using finite element analysis software. Theoretical software needle buckling analysis detected the load for the first buckling mode of the needle, when the highest value was reached for the G20 needle with the load 18.8 N. The load for G21 needle was 9.7 N and for G23 8 N. Experimental data with customized tensile-compression device aligned theoretical data when the highest value was reached for the G20 needle with the load 19.7±1.9 N. The load for G21 needle was 10.6+/-2.7 N and for G23 7.9+/-0.7 N. Theoretical and practical experiments have shown that the standard G20 needle model exhibits the highest mechanical tolerance for potential interventions in the musculoskeletal system. Key words Interventional ultrasound " Needle " Buckling strength.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-03-13
Primary Topic
Anesthesia and Pain Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Analysis of Needles Used in Ultrasound-Guided Musculoskeletal Interventions.

Tomáš Novotný, K Mezian, L Özçakar, D Hadraba
PubMed
Anesthesia and Pain Management
article

Mechanical Analysis of Needles Used in Ultrasound-Guided Musculoskeletal Interventions.

Tomáš Novotný, K Mezian, L Özçakar, D Hadraba
article en

Abstract

We performed a mechanical analysis of the commonly used needles for ultrasound-guided interventions in the musculoskeletal system. Specifically, focusing on the ability to absorb potential physical loads and the degree of deformation during the procedure, the needle gauge best suited for those procedures is evaluated. A customized tensile-compression device was used for an experimental buckling strength test on three commonly used needle types with specific gauge sizes. The loss of structural integrity, loss of needle stability, and buckling load were modeled also theoretically using finite element analysis software. Theoretical software needle buckling analysis detected the load for the first buckling mode of the needle, when the highest value was reached for the G20 needle with the load 18.8 N. The load for G21 needle was 9.7 N and for G23 8 N. Experimental data with customized tensile-compression device aligned theoretical data when the highest value was reached for the G20 needle with the load 19.7±1.9 N. The load for G21 needle was 10.6+/-2.7 N and for G23 7.9+/-0.7 N. Theoretical and practical experiments have shown that the standard G20 needle model exhibits the highest mechanical tolerance for potential interventions in the musculoskeletal system. Key words Interventional ultrasound " Needle " Buckling strength.

PubMedVol. 75(1)
Jan Evangelista Purkyně University in Ústí nad Labem (CZ)
Openalex Percentile: Top 23%
Anesthesia and Pain Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.