Utilization of a thorax anthropomorphic phantom for dose assessment and scanning protocol synchronization in computed tomography

Optimizing radiation dose while maintaining image quality remains a key challenge in computed tomography (CT). This study used a thorax-specific anthropomorphic phantom to assess patient dose, image quality, and artefact presence under automated tube current modulation settings and to evaluate the effect of tube voltage on Hounsfield Unit (HU) response for different iodine concentrations. Dose metrics, noise levels, and image quality indicators were extracted from Digital Imaging and Communications in Medicine (DICOM) metadata and image analysis. The study examined how patient positioning affects modulation performance and how tube voltage influences HU values in iodinated inserts. Results revealed inconsistencies in dose modulation across CT systems and highlighted the importance of synchronized protocols. A methodology was proposed to harmonize scanning protocols, ensuring consistent image quality and improved patient safety. These findings demonstrate the value of anthropomorphic phantoms in validating and optimizing CT protocols across clinical environments.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-12-23
DOI
https://doi.org/10.1093/rpd/ncaf192
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilization of a thorax anthropomorphic phantom for dose assessment and scanning protocol synchronization in computed tomography

Mahira Redžić, Fuad Zukić, Sabina Prevljak, Amra Skopljak-Beganović et al.
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Utilization of a thorax anthropomorphic phantom for dose assessment and scanning protocol synchronization in computed tomography

Mahira Redžić, Fuad Zukić, Sabina Prevljak, Amra Skopljak-Beganović, Adnan Beganović, Tarik Seferović, Melika Damadžić
article en

Abstract

Optimizing radiation dose while maintaining image quality remains a key challenge in computed tomography (CT). This study used a thorax-specific anthropomorphic phantom to assess patient dose, image quality, and artefact presence under automated tube current modulation settings and to evaluate the effect of tube voltage on Hounsfield Unit (HU) response for different iodine concentrations. Dose metrics, noise levels, and image quality indicators were extracted from Digital Imaging and Communications in Medicine (DICOM) metadata and image analysis. The study examined how patient positioning affects modulation performance and how tube voltage influences HU values in iodinated inserts. Results revealed inconsistencies in dose modulation across CT systems and highlighted the importance of synchronized protocols. A methodology was proposed to harmonize scanning protocols, ensuring consistent image quality and improved patient safety. These findings demonstrate the value of anthropomorphic phantoms in validating and optimizing CT protocols across clinical environments.

Radiation Protection DosimetryVol. 202(3–4)
University of Sarajevo (BA), University Clinical Center Tuzla (BA)
Good health and well-being
Openalex Percentile: Top 25%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Utilization of a thorax anthropomorphic phantom for dose assessment and scanning protocol synchronization in computed tomography — Mahira Redžić, Fuad Zukić, et al. · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS