From guideline to practice: A single-center evaluation of the ‘action corridor’ model and generative AI for PET/CT quality management

Harmonizing institutional Standard Operating Procedures (SOPs) with international PET/CT guidelines is complex and resource intensive. This study evaluates the ‘Action Corridor’ model for structured ‘to-be’/‘as-is’ comparison and assesses a generative AI-assisted workflow for extracting quality-relevant parameters from heterogeneous documentation in a single-centre setting. Current EANM/SNMMI guidelines were systematically compared with institutional SOPs for [ 18 F]FDG, [ 68 Ga]Ga-PSMA, and [ 68 Ga]Ga-DOTATOC PET/CT using a four-category framework (Conformity, Specification, Justified Adaptation, Potential Inconsistency). A generative AI model extracted predefined quantitative parameters from unstructured SOPs. AI-extracted values were cross-checked against independent human review. Overall harmonisation was high across protocols. Quantitative deviations were mainly observed in uptake times (practice-to-guideline ratios 0.41–0.75), most pronounced for [ 68 Ga]Ga-DOTATOC (30 min vs. 55–90 min). Reduced effective radiation exposure was achieved for [ 18 F]FDG (ratio 0.83). No discrepancies were identified in the predefined quantitative parameters compared with human verification. The ‘Action Corridor’ model enables transparent identification of guideline–practice deviations while preserving justified local adaptations. Generative AI reliably supports structured parameter extraction in quality management workflows. In this single-centre proof-of-concept setting, the framework demonstrates methodological feasibility. Empirical scalability across institutions requires prospective multicentre validation. • The ‘Action Corridor’ model visualises guideline vs. practice deviations in PET/CT. • Generative AI effectively organises unstructured QM data for analysis. • Framework supports continuous improvement cycles (PDCA) required by ISO 9001.

Authors

Institutions

Publication Details

Journal
EANM Innovation
Published
2026-03-13
DOI
https://doi.org/10.1016/j.eanmi.2026.100164
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From guideline to practice: A single-center evaluation of the ‘action corridor’ model and generative AI for PET/CT quality management

Florian Christoph Gaertner, Maria Holstensson, Markus Essler, Caroline Stokke et al.
EANM Innovation
Radiomics and Machine Learning in Medical Imaging
article

From guideline to practice: A single-center evaluation of the ‘action corridor’ model and generative AI for PET/CT quality management

Florian Christoph Gaertner, Maria Holstensson, Markus Essler, Caroline Stokke, Ivalina Hristova, Barbara Kreppel, Alois M. Sprinkart, MILKA MARINOVA, Ole Lajord Munk, Mahnaz Shekari, Simon Koenig, Ronald Boellaard, Sebastian Nowak, Takahiro Higuchi, Oleg Obolenski, Vicky Goh
article en

Abstract

Harmonizing institutional Standard Operating Procedures (SOPs) with international PET/CT guidelines is complex and resource intensive. This study evaluates the ‘Action Corridor’ model for structured ‘to-be’/‘as-is’ comparison and assesses a generative AI-assisted workflow for extracting quality-relevant parameters from heterogeneous documentation in a single-centre setting. Current EANM/SNMMI guidelines were systematically compared with institutional SOPs for [ 18 F]FDG, [ 68 Ga]Ga-PSMA, and [ 68 Ga]Ga-DOTATOC PET/CT using a four-category framework (Conformity, Specification, Justified Adaptation, Potential Inconsistency). A generative AI model extracted predefined quantitative parameters from unstructured SOPs. AI-extracted values were cross-checked against independent human review. Overall harmonisation was high across protocols. Quantitative deviations were mainly observed in uptake times (practice-to-guideline ratios 0.41–0.75), most pronounced for [ 68 Ga]Ga-DOTATOC (30 min vs. 55–90 min). Reduced effective radiation exposure was achieved for [ 18 F]FDG (ratio 0.83). No discrepancies were identified in the predefined quantitative parameters compared with human verification. The ‘Action Corridor’ model enables transparent identification of guideline–practice deviations while preserving justified local adaptations. Generative AI reliably supports structured parameter extraction in quality management workflows. In this single-centre proof-of-concept setting, the framework demonstrates methodological feasibility. Empirical scalability across institutions requires prospective multicentre validation. • The ‘Action Corridor’ model visualises guideline vs. practice deviations in PET/CT. • Generative AI effectively organises unstructured QM data for analysis. • Framework supports continuous improvement cycles (PDCA) required by ISO 9001.

EANM InnovationVol. 3
Oslo University Hospital (NO), Karolinska University Hospital (SE), Okayama University (JP), King's College London (GB), Aarhus University (DK), University Hospital Bonn (DE), Aarhus University Hospital (DK), Karolinska Institutet (SE), European Association of Nuclear Medicine (AT), Universitätsklinikum Würzburg (DE), Barcelonaβeta Brain Research Center (ES), Amsterdam University Medical Centers (NL), Artificial Intelligence in Medicine (Canada) (CA), University College London (GB)
Openalex Percentile: Top 23%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.