ClotPro® haemostasis in pregnancy: physiological parameters, reference intervals and comparison with non-pregnant women in a prospective observational study

Severe haemorrhage remains a leading cause of maternal mortality worldwide, despite advancements in obstetric care. Although viscoelastic testing is recommended to guide treatment of postpartum haemorrhage, device-specific physiological parameters and reference ranges specific to pregnancy are necessary to enable accurate interpretation of viscoelastic findings in the clinical management of obstetric patients. Evaluation of ClotPro®, including comparison with conventional laboratory assays and with non-pregnant individuals, is therefore essential to support its use in obstetric patients. In this prospective study, venous blood samples were obtained from 130 parturient participants before labour and 45 non-pregnant controls. Samples were analysed with conventional laboratory coagulation tests and the ClotPro® device. ClotPro® parameters and conventional laboratory tests were compared between the parturient population and non-pregnant control group with Student’s t-test or the Mann-Whitney U test, as appropriate. The correlation between selected laboratory and coagulation parameters was assessed with Spearman’s correlation coefficient. Reference ranges for ClotPro® in parturients were established by calculation of percentiles 2.5 and 97.5. Significant statistical differences in clot firmness were found across the EX-test, IN-test, and FIB-test (p < 0.006) between parturient and non-pregnant participants. The most pronounced differences were observed in the FIB-test. Strong correlation was observed between conventional laboratory tests and FIB-test (Rs = 0.657, p < 0.001 in the pregnant group; Rs = 0.669, p < 0.001 in the control group). According to our findings, reference ranges were established for the parturient population: EX-test, CT (39–67 s), A5 (39–59 mm), ML (1–9%), MCF (57–70 mm); FIB-test, A5 (15–29 mm), MCF (19–35 mm); and IN-test, CT (121–172 s). Pregnant women exhibit a distinct ClotPro® coagulation profile, characterised by increased clot firmness in FIB-test, supported by correlations with standard laboratory tests and parturient-specific reference intervals. These findings enhance the physiological interpretation of ClotPro® in obstetric care and may support its future integration into postpartum haemorrhage management.

Authors

Institutions

Publication Details

Journal
BMC Pregnancy and Childbirth
Published
2026-03-13
DOI
https://doi.org/10.1186/s12884-026-08941-5
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ClotPro® haemostasis in pregnancy: physiological parameters, reference intervals and comparison with non-pregnant women in a prospective observational study

Roman Gál, Ondřej Hrdý, Kamil Vrbica, Lukáš Hruban et al.
BMC Pregnancy and Childbirth
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

ClotPro® haemostasis in pregnancy: physiological parameters, reference intervals and comparison with non-pregnant women in a prospective observational study

Roman Gál, Ondřej Hrdý, Kamil Vrbica, Lukáš Hruban, Jan Štingl, P Janků, Kateřina Vaníčková, R. Stepanova
article en

Abstract

Severe haemorrhage remains a leading cause of maternal mortality worldwide, despite advancements in obstetric care. Although viscoelastic testing is recommended to guide treatment of postpartum haemorrhage, device-specific physiological parameters and reference ranges specific to pregnancy are necessary to enable accurate interpretation of viscoelastic findings in the clinical management of obstetric patients. Evaluation of ClotPro®, including comparison with conventional laboratory assays and with non-pregnant individuals, is therefore essential to support its use in obstetric patients. In this prospective study, venous blood samples were obtained from 130 parturient participants before labour and 45 non-pregnant controls. Samples were analysed with conventional laboratory coagulation tests and the ClotPro® device. ClotPro® parameters and conventional laboratory tests were compared between the parturient population and non-pregnant control group with Student’s t-test or the Mann-Whitney U test, as appropriate. The correlation between selected laboratory and coagulation parameters was assessed with Spearman’s correlation coefficient. Reference ranges for ClotPro® in parturients were established by calculation of percentiles 2.5 and 97.5. Significant statistical differences in clot firmness were found across the EX-test, IN-test, and FIB-test (p < 0.006) between parturient and non-pregnant participants. The most pronounced differences were observed in the FIB-test. Strong correlation was observed between conventional laboratory tests and FIB-test (Rs = 0.657, p < 0.001 in the pregnant group; Rs = 0.669, p < 0.001 in the control group). According to our findings, reference ranges were established for the parturient population: EX-test, CT (39–67 s), A5 (39–59 mm), ML (1–9%), MCF (57–70 mm); FIB-test, A5 (15–29 mm), MCF (19–35 mm); and IN-test, CT (121–172 s). Pregnant women exhibit a distinct ClotPro® coagulation profile, characterised by increased clot firmness in FIB-test, supported by correlations with standard laboratory tests and parturient-specific reference intervals. These findings enhance the physiological interpretation of ClotPro® in obstetric care and may support its future integration into postpartum haemorrhage management.

BMC Pregnancy and Childbirth
Masaryk University (CZ), University Hospital Brno (CZ)
Openalex Percentile: Top 26%
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.