Dual-energy lattice-tip catheter for posterior mitral line ablation: acute efficacy and 1-year outcomes

Achieving durable mitral isthmus (MI) block remains challenging. A novel dual-energy lattice-tip catheter enables delivery of both pulsed field (PF) and radiofrequency (RF) energy, potentially improving lesion quality and clinical outcomes. This study aims to assess the feasibility, acute success, safety, and 1-year outcomes of posterior mitral line (PML) ablation using this novel catheter in a multicenter cohort. Consecutive patients from two European centers undergoing atrial fibrillation ablation with PML using the dual-energy system (PF-only or PF/RF, at operator discretion) were prospectively enrolled. Primary outcomes were acute MI conduction block, periprocedural complications, and arrhythmia-free survival at follow-up. Among 102 patients, PML was performed with PF-only in 80.4% and PF/RF in 19.6%. Acute MI block was achieved in 92.2% (91.5% PF-only, 95.0% PF/RF, no statistically significant difference). After a median follow-up of 356 days, 74.5% of patients were free from atrial arrhythmia (65.6% in first-time ablation), and arrhythmia-free survival appeared higher with PF/RF than PF-only (85.0% vs 72.0%), but not statistically different. Two major (ventricular fibrillation and coronary vasospasm) and five minor complications were reported. Nine patients (8.8%) underwent redo procedures. Durable MI block was confirmed in two cases, while epicardial gaps accounted for 71.4% of the seven patients with reconduction. PML ablation with a dual-energy lattice-tip catheter provided high acute MI block rates, an overall favorable safety profile, and encouraging 1-year outcomes. The potential impact of combined PF/RF energy and epicardial strategies on lesion durability should be evaluated in further randomized studies. Posterior mitral isthmus ablation with the dual-energy lattice-tip catheter provided high acute block rates, an overall favorable safety profile, and encouraging 1-year outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Interventional Cardiac Electrophysiology
Published
2026-03-13
DOI
https://doi.org/10.1007/s10840-026-02294-x
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-energy lattice-tip catheter for posterior mitral line ablation: acute efficacy and 1-year outcomes

Roberto Menè, Kazutaka Nakasone, Stéphane Combes, Giampaolo Vetta et al.
Journal of Interventional Cardiac Electrophysiology
Atrial Fibrillation Management and Outcomes
article

Dual-energy lattice-tip catheter for posterior mitral line ablation: acute efficacy and 1-year outcomes

Roberto Menè, Kazutaka Nakasone, Stéphane Combes, Giampaolo Vetta, Andrea Sarkozy, Alexandre Almorad, JP. Albenque, G B Chierchia, Domenico Giovanni Della Rocca, Serge Boveda, Antonio Sorgente, Nicolas Combes, Wael Zaher, Carlo de Asmundis
article en

Abstract

Achieving durable mitral isthmus (MI) block remains challenging. A novel dual-energy lattice-tip catheter enables delivery of both pulsed field (PF) and radiofrequency (RF) energy, potentially improving lesion quality and clinical outcomes. This study aims to assess the feasibility, acute success, safety, and 1-year outcomes of posterior mitral line (PML) ablation using this novel catheter in a multicenter cohort. Consecutive patients from two European centers undergoing atrial fibrillation ablation with PML using the dual-energy system (PF-only or PF/RF, at operator discretion) were prospectively enrolled. Primary outcomes were acute MI conduction block, periprocedural complications, and arrhythmia-free survival at follow-up. Among 102 patients, PML was performed with PF-only in 80.4% and PF/RF in 19.6%. Acute MI block was achieved in 92.2% (91.5% PF-only, 95.0% PF/RF, no statistically significant difference). After a median follow-up of 356 days, 74.5% of patients were free from atrial arrhythmia (65.6% in first-time ablation), and arrhythmia-free survival appeared higher with PF/RF than PF-only (85.0% vs 72.0%), but not statistically different. Two major (ventricular fibrillation and coronary vasospasm) and five minor complications were reported. Nine patients (8.8%) underwent redo procedures. Durable MI block was confirmed in two cases, while epicardial gaps accounted for 71.4% of the seven patients with reconduction. PML ablation with a dual-energy lattice-tip catheter provided high acute MI block rates, an overall favorable safety profile, and encouraging 1-year outcomes. The potential impact of combined PF/RF energy and epicardial strategies on lesion durability should be evaluated in further randomized studies. Posterior mitral isthmus ablation with the dual-energy lattice-tip catheter provided high acute block rates, an overall favorable safety profile, and encouraging 1-year outcomes.

Journal of Interventional Cardiac Electrophysiology
Heart Rhythm Society (US), Université Libre de Bruxelles (BE), Centre Hospitalier Universitaire Brugmann (BE), Universitair Ziekenhuis Brussel (BE), Clinique Pasteur (FR), Kobe University (JP)
Affordable and clean energy
Openalex Percentile: Top 31%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.